Residential Installation; Clearances - Pacific energy ALDERLEA T5 LE Operating And Installation Instructions

Table of Contents

Advertisement

Clearances:

18"
457mm
127mm
15"
381mm
Figure 4: T5 Minimum clearances.
Clearances may be reduced with various heat shielding/insulating materials. Consult CSA B365 or NFPA 211
and local re codes and authorities for approval. For close clearances, use a listed double-wall connector.
NOTE: local/national codes or regulations may override some guidelines in this manual
We recommend that our products be installed and /or serviced by professionals who are certified by
one of the following;
NFI (National Fireplace Institute®) in the United States,
CSIA (Chimney Safety Institute of America) in the United States and Canada,
WETT (Wood Energy Technology Transfer) in Canada or
APC (Association des Professionnels du Chauffage) in Quebec
ALT5-LE 140623-28

Residential Installation

Single Wall Connector - Residential
8"
203mm
14"
356mm
26"
660mm
5"
Double Wall Connector - Residential
15"
14"
381mm
356mm
14"
356mm
26"
660mm
Alcove: Min. Height 7'(2.13m)
Max. Depth 3'(914 m m)
533mm
7"
178mm
5"
127mm
14"
356mm
26"
6601mm
13
7"
178mm
21"
4"
18"
457mm
102mm
4"
102mm
100000353