Floor Protector - Pacific energy ALDERLEA T5 LE Operating And Installation Instructions

Table of Contents

Advertisement

The stove may be installed on a combustible oor provided noncombustible ember protection is used.
This protection must extend as follows:
U.S.A. Only
Minimum Width - 34"(864mm)
Minimum Overall Depth - 40 1/2"(1.03m)
4"
101mm
8"
203mm
16" [406mm]
Figure 2: T5 Floor protector - USA
100000353

Floor Protector

Non-combustible
floor protector
8"
203mm
In Canada: 18" (457 mm) on
the ring side and 8" (203 mm)
to the other sides.
In USA: 16" (406 mm) to the front and 8"
(203 mm) to the sides of the fuel loading
door opening. See Figure #4, below.
This protection is also required under
the chimney connector and 2" (51 mm)
beyond each side if using any horizontal
venting.
Canada Only
Minimum Width - 40'(1.02m)
Minimum Overall Depth - 50 1/2"(1.28m)
18" [457mm]
Figure 3: T5 Floor protector - Canada.
12
8" [203mm]
Non-combustible
floor protector
ALT 5-LE 140623-28