Summary of Contents for Pacific energy SUPER INSERT LE
Page 1
Meets the US Environmental Protection Agency's 2020 Particulate Emission Standards. MODEL: SUPER INSERT LE Visit www.pacificenergy.net for the most recent version of this manual 210619-28 SUPER INSERT LE 100002686...
TOUCH GLASS. PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the Pacific Energy, SUPER INSERT LE; Fireplace Insert wood heater. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.
COMBUSTIBLE SOUS L’APPAREIL, S’ÉTENDANT À UNE DISTANCE DE 16po / 406mm DEVANT LE FACE D’OUVERTURE DU FOYER. CLEARANCE TO COMBUSTIBLES • INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND • INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DE OPERATING INSTRUCTIONS.
Chimney fires are easy to detect; they usually involve one or more of the following: • Flames and sparks shooting out of the top of the chimney • A roaring sound • Vibration of the chimney 100002687 SUPER INSERT LE 210619-28...
If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container. SUPER INSERT LE 210619-28 100002686...
It is damp if it turns black and lights within three minutes. If it sizzles, hisses and blackens without igniting in five minutes it is soaked and should not be burnt. 100002687 SUPER INSERT LE 210619-28...
Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater and chimney. A glowing red top or vent pipe are indications of overfiring. Failure to rectify an over firing condition can be hazardous and may void the manufacturer's warranty. SUPER INSERT LE 210619-28 100002686...
Leave an ash bed approximately 1" (25 mm) deep on the firebox bottom to help maintain a hot charcoal bed. See section "Disposal of Ashes" on page 5. 100002687 SUPER INSERT LE 210619-28...
REPLACEMENTS. Door Gaskets - The gasket used by Pacific Energy (7/8"(22mm) medium density fiberglass rope) requires only light pressure to seal. This will prolong seal life. It is important that the door seal be maintained in good condition. Periodically inspect seals and replace if necessary. Follow the instructions included in the kit (prt# 80000156). The kit can be obtained from your nearest Pacific Energy dealer.
Tilt baffle sideways to drop down and remove from firebox. Inspect gasket between baffle and supply tube. If necessary, replace with gasket part number 80000365, available from your Pacific Energy dealer. Re-install baffle assembly in reverse order. The two side pieces of insulation must be tight against the side rails.
The fireplace's non-combustible masonry hearth must extend 16” in front and 8” beyond each side of the existing fireplace opening. See Figure 2. ” 660mm ” 570mm ” 535mm ” 465mm ” Fireplace Hearth ” 406mm 200mm Figure 2: Fireplace opening dim. - Super Insert LE. 100002687 SUPER INSERT LE 210619-28...
USA: 16” Ember Protection Masonry Hearth Figure 3: Super Insert LE - Ember protection. Optional Leveling Legs Leveling legs(bolts) are provided if you need them to level or steady the insert on an uneven hearth. • If you fireplace is lower than the hearth mount the rear leveling leg bolts. Prop the unit up to access threaded inserts under the sides towards the rear of the unit.
255mm Fireplace Hearth 6” 155mm Figure 4: SUPER Insert LE Clearances. Minimum Clearances to Combustibles Side of Blower Cover to Adjacent Sidewall........10 in.(255 mm.) Side of Blower Cover to Side Facing (max 3-1/2 in. deep)....6 in.(155 mm.) Top of Cast top to Mantel Facing............ 12 in.(305 mm.) Top of Cast Top to Mantel (max 12in.
National Building Code. A metal tag is provided and is to be fastened to the back wall of the fireplace, If the fireplace has been modified to accommodate the insert. SUPER INSERT LE 210619-28 100002686...
Page 16
9. Attach a rain cap to the end of the liner. A storm collar may be used if desired. Figure 5: Super Insert LE full flue liner. 10. Install the surround See "Surround Assembly and Installation" on page 20, Re-Install the top and Blower covers in the reverse order they were removed.
Page 17
Direct Flue Connection (permitted only in the USA) Pacific Energy highly recommends the use of a full liner as the safest installation and providing optimum performance. When connected to a full liner, the Insert is able to draft correctly and will prevent problems such as difficult start-ups and smoking out the door.
Decorative Cover and tighten screws (Figure 7). Combustion Air will be drawn from the room through the front of the unit. Decorative Cover Room Air Cover Screws Screws Figure 7: Super Insert LE - Room Air Supply Covers. 100002687 SUPER INSERT LE 210619-28...
2. Lift up on the panel to release the catches and pull towards you. Lift the cover up, and under the Top and then pull out from the bottom to remove it (Figure 10) left side shown. cover mounting screw Figure 9: Front cover screw location. Figure 10: Panel removal. SUPER INSERT LE 210619-28 100002686...
8. Re-install the decorative top by aligning the wing bolts in the slots and pushing it back gently against the surround. Tighten the Wing Bolts. 9. Install the Fan Cover panels, the outer tabs of the covers use the same slots as the surround. 100002687 SUPER INSERT LE 210619-28...
Figure 15: Bolts securing ash lip to firebox. Wire Support Tab Screw Figure 17: Removing speed control assy. Figure 16: Wire Guides. SUPER INSERT LE 210619-28 100002686...
Page 22
Ensure that the power cable is correctly routed through the surround and it is not touching the firebox side. Wire placement is important to prevent damage to wires. Figure 20: Removing thermal switch. Figure 21: Relocating thermal switch to left side. 100002687 SUPER INSERT LE 210619-28...
- Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, - Consult Dealer SUPER INSERT LE 210619-28 100002686...
Firebrick Installation Figure 22: Super Insert LE Brick layout. ITEMS TO USE: SIZE 18pcs. 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 2pc. 9” x 1 3/8” x 1 1/4” (184 mm x 115 mm x 32 mm) The Brick Pack that came with your stove is used on several models and will have extra bricks Figure 23: Bottom shield.
Page 25
Note: Even though the far bricks on both side walls will fit completely behind the rear wall end bricks, do not do this as the resulting gaps in the side wall bricks at the front will be too large. Figure 28: Rear wall bricks in place. Figure 29: Right wall bricks in place. SUPER INSERT LE 210619-28 100002686...
(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM ..DESCRIPTION ................PART # 1..... Cast, Top w/ hardware, Super Insert, ..........80002305 2..... Fan Cover, Super Insert LE ..............80002309 3..... Blower Assy, c/w brackets, Latch Side, ..........80002257 4....Blower Only, Latch Side ..............80000904 5....
Page 27
All parts may be ordered from your nearest Pacific Energy dealer. Contact Pacific Energy for the location of the dealer nearest you. SUPER INSERT LE 210619-28 100002686...