Warning: Under no circumstances is this
heater to be installed in a makeshift or
"temporary" manner. It may be red only
after the following conditions have been
met.
DO NOT CONNECT THIS UNIT
TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
DO NOT INSTALL IN A SLEEPING
ROOM.
CAUTION: THE STRUCTURAL
INTEGRITY OF THE MOBILE HOME
FLOOR, WALLS AND CEILING/
ROOF MUST BE MAINTAINED.
The stove must be permanently
anchored to the oor. Use the holes
located in the bottoms of the legs.
Outside air supply must be used for
Mobile Home installations -
This heater must be installed with listed double-wall connector and compatible ULC-S629 or UL-103HT
listed chimney system.
NOTE: Install all chimney components to the connector and chimney manufacturer's installation
requirements. Consult your chimney supplier/manufacturer for installation advice.
Consult local Builing codes and Fire authorities for approval.
ALT5-LE 140623-28
Follow chimney manufacture specifcations for
distance between vent termination heigth and
chimney at roof line. Also consult local building
regulations.
Listed
Insulated
Chimney
Minimum 7' [2.1m]
Ceiling Height
55" [1.4m]
Minimum
Non-combustible
Ember Protector
4" (102 mm) diameter metal air inlet
ducting with rodent screen.
* If the crawl space is well ventilated
it is not necessary to extend air inlet
to outside.
Figure 12: T5 Mobile Home venting.
21
Listed
Double wall
Chimney
connector
Legs Bolted to Floor
100000353
4" diameter hooded
air inlet or 90 elbow
turned down with
rodent screen.