Warning: Under no circumstances is this
heater to be installed in a makeshift or
"temporary" manner. It may be red only
after the following conditions have been
met.
•
DO NOT CONNECT THIS UNIT
TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
•
DO NOT INSTALL IN A SLEEPING
ROOM.
•
CAUTION: THE STRUCTURAL
INTEGRITY OF THE MOBILE HOME
FLOOR, WALLS AND CEILING/
ROOF MUST BE MAINTAINED.
•
The stove must be permanently
anchored to the oor. Use the holes
located in the bottoms of the legs.
•
Outside air supply must be used for
Mobile Home installations -
•
This heater must be installed with listed double-wall connector and compatible ULC-S629 or UL-103HT
listed chimney system.
NOTE: Install all chimney components to the connector and chimney manufacturer's installation
requirements. Consult your chimney supplier/manufacturer for installation advice.
Consult local Builing codes and Fire authorities for approval.
ALT5-LE 140623-28
Follow chimney manufacture specifcations for
distance between vent termination heigth and
chimney at roof line. Also consult local building
regulations.
Listed
Insulated
Chimney
Minimum 7' [2.1m]
Ceiling Height
55" [1.4m]
Minimum
Non-combustible
Ember Protector
4" (102 mm) diameter metal air inlet
ducting with rodent screen.
* If the crawl space is well ventilated
it is not necessary to extend air inlet
to outside.
Figure 12: T5 Mobile Home venting.
21
Listed
Double wall
Chimney
connector
Legs Bolted to Floor
100000353
4" diameter hooded
air inlet or 90 elbow
turned down with
rodent screen.