Connecting the feeder cable
Attention
If the power supply cable is
damaged, it must be replaced
only by an authorised service
agent in order to avoid a
hazard.
To connect the feeder cable to the
cooker it is necessary to:
* Remove the two screws that hold
shield "A" behind the cooker.
* Open completely the cable clamp "D".
* Position the U bolts onto terminal block "B" (fig. 10.1) ccording to the
diagram in figs. 10.2a, 10.2b, 10.2c.
230 V ac
230 V~
3
5
1
2
4
N
PE
L
1
(L
)
230 V ac
230 V~
2
1
2
3
4
5
N
L
1
(L
)
1
2
3
4
5
2
N(L
)
2
L1
PE
1
2
3
4
5
Fig. 10.2a
N(L
)
2
L1
Fig. 10.2a
400 V 2N ac
400 V 2N~
3
1
2
4
L
L
N
1
2
1
400 V 2N ac
400 V 2N~
1
2
3
PE
L
L
N
1
2
1
2
3
4
L1
L2
1 N
2 N
1
2
3
4
Fig. 10.2b
1 N
L1
L2
PE
Fig. 10.2b
67
D
Fig. 10.1
D
Fig. 10.1
400 V 2N ac
400 V 2N~
5
1
2
N
PE
L
2
1
400 V 2N ac
400 V 2N~
4
5
1
2
N
PE
L
1
2
5
1
2
L1
L2
PE
5
1
2
Fig. 10.2c
2 N
L1
PE
Fig. 10.2c
B
B
A
A
3
5
4
L
N
PE
2
3
4
5
L
N
PE
1
2
3
4
5
N
PE
3
4
5
N
L2
PE