24 Hour Zone Types

24 Hour zones (Fire, PA and Tamper), Keyswitch zones and Push
to Set zones should be monitored constantly.
When a zone is omitted the system no longer monitors opening
and closing of that zone. The Full and Part Set Suites (see page
29) provide a method of automatically omitting zones when the
system is set. Once a zone is omitted it will not be re-included until
the system is next set. It is important to ensure that 24 Hour zones
(Fire, PA and Tamper), Keyswitch zones and Push to Set zones
are not omitted by any of the Full or Part Set Suites or the Cleaner
Suite.
The system can be programmed to automatically change the Zone
Type of any zone into either Exit/Entry, Inhibited Entry or Guard on
selected part sets (see page 26). The change will persist until the
system is unset. It is important to ensure that 24 Hour zones (Fire,
PA and Tamper), Keyswitch zones and Push to Set zones are not
changed on part set.
If EN 50131-1 Requirements is selected (see page 20) then
omitted zones will be reinstated when the system is next
unset.
When wiring a 24 Hour zone (Fire, PA and Tamper), such as a
panic button, using EOL operation it may be more convenient to fit
the EOL resistor(s) in the panel than in the detector.

Programming the Zone Type

Each of the eight Zone Types has an associated Zone Type
number which is used when programming the Zone Type of a
zone:
Zone Type Number
1
2
3
4
5
6
7
8
From the Programming Menu, press
number. The Zone Type currently selected will indicate i.e. Guard.
Zon es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the Zone Type number required. Press
system will chime to confirm the new Zone Type has been
accepted. The system will then automatically revert to the
Programming Menu.
26
-


Zone Type
Push to Set
Inhibited Entry
Guard
Fire
Tamper
Entry/Exit
Personal Attack (Panic)
Keyswitch
followed by the zone


. The
Veritas R8 Plus & Excel Installation Manual
For example to program Zone 7 as a Guard zone, enter
press
, press
.
Key

Program Zone Type

Zone = 7

Zone Type = Guard

Program
A zone is often referred to by its Zone Type, e.g. a zone with
the PA Zone Type would be referred to as a PA zone.

Changing Part Set Zone Types

The Zone Type of any zone can be made to change when the system
is part set. The Zone Type can be changed into either Entry/Exit,
Inhibited Entry or Guard. It is also possible to program which part
set(s) will cause the Zone Type to change. The change will persist until
the system is next unset.
For example, the tables below show the factory settings:
Zone
Zone Type
1
Entry/Exit
2
Inhibited Entry
3
Guard
4
Guard
5
Guard
6
Guard
7
Guard
8
Guard
Zone 1 will change (from Entry/Exit) into Guard and Zone 2 will
change (from Inhibited Entry) into Entry/Exit.
Part Set Number

Part Set 1
Part Set 2
Part Set 3
Part Set 4
These changes will occur when using Part Sets 1 and 3 but not
when using Part Sets 2 and 4.
24 Hour zones (Fire, PA and Tamper), Keyswitch zones and
Push to Set zones should be monitored constantly and
should NOT be programmed to change when the system is
part set.
Description
 - 
Part Setting Changes Zone Type
Into:
Inhibited
Entry/Exit
Entry
Guard



Zone Type Changes For Part Set
INS045-14

,