Programming Part Sets Zone Changes

The Control Panel has four part sets. Zone Types will only be
changed on selected part sets. For example the Control Panel is
factory set with Part Sets 1 and 3 selected. Thus Zone Types will
only be changed on Part Set 1 and Part Set 3, not on Part Set 2 or
Part Set 4.
From the Programming Menu, enter
selected will indicate.
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) of the part set(s) to
be selected or de-selected. Press
chime to confirm that the new selection has been accepted. The
system will then automatically revert to the Programming Menu.

Changing Zones to Entry/Exit

This suite defines the zones which will be changed into Entry/Exit
zones on the selected part sets. For example the Control Panel is
factory set with Zone 2 included. Thus the Zone Type of Zone 2 will
be changed (from Inhibited Entry) into Entry/Exit on Part Sets 1
and 3.
From the Programming Menu, enter
currently included will indicate.
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new suite has been accepted. The system will then
automatically revert to the Programming Menu.

Changing Zones to Inhibited Entry

This suite defines the zones which will be changed into Inhibited
Entry zones on the selected part sets. For example the Control Panel
is factory set with no zones included. Thus no zones will be changed
into Inhibited Entry.
From the Programming Menu, enter
currently included will indicate.
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new suite has been accepted. The system will then
automatically revert to the Programming Menu.
INS045-14

. The part sets currently


. The system will

. The zones that are


. The system will chime to

. The zones that are


. The system will chime to


Changing Zones to Guard

This suite defines the zones which will be changed into Guard
zones on the selected part sets. For example the Control Panel is
factory set with Zone 1 included. Thus the Zone Type of Zone 1 will
be changed (from Entry/Exit) into Guard on Part Sets 1 and 3.
From the Programming Menu, enter
currently included will indicate.
1 2 3 4 5 6 7 8
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new suite has been accepted. The system will then
automatically revert to the Programming Menu.

Programming the Date and Time


It is ESSENTIAL to program the current date (
time (
and the 250 Event Extended Log.
Programming the service timers (
prevented unless the current date (
programmed.
If the panel is completely powered down it will attempt to store
the current time and date in NVM and continue from this point
when it is powered up. However it may be also desirable to
select the Engineer Reset on Power Up option (see page 21).

Programming the Date

From the Programming Menu, enter
like this.

1 2 3 4 5 6 7 8
Enter the current date as a 6 digit number; Day, Day, Month,
Month, Year, Year (e.g. to program the 1st of June 1998 enter

new date is entered. Press
confirm the new date has been accepted. The system will then
automatically revert to the Programming Menu and all the zone
lights will illuminate.
Programming the Control Panel

Z on es

U n set
T am p er

. The system will chime to

) for correct operation of the service timer(s)


Z on es

U n set

T am p er
). The display will indicate as each digit of the
. The system will chime to

. The zones that are
 - 

) and
,

,

) is

) has first been

. The display will look
27