Programming the Control Panel
Option 6 - Push To Set
The user starts full set in the usual way and leaves the premises.
However the system will ONLY set when an external push button is
pressed.
Ensure the zone is set as Push to Set (see page 25).
If this zone is set to chime (see User Guide) then the push
button can double up as a door bell.
If a normally open (N/O) push button is used then the zone
should be inverted (see page 31).
Push to Set does not operate in part set.
Option 7 - Strobe Flash on Full Set
When 'ON' the external strobe will flash momentarily to indicate
that the alarm has set.
Option 8 - Invert Switched Positive Output
When 'ON' the operation of the Switched Positive output (SW+) is
inverted.

Miscellaneous Selections Three

From the Programming Menu, enter
the options currently selected.
Zon es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) to select or de-
select the corresponding option(s) as shown on the display.
To display an explanation of the Misc. options associated
with a particular number, press and hold the corresponding
key
(LCD Keypad only).
Press
. The system will chime to confirm that the new
options have been accepted. The system will then automatically
revert to the Programming Menu.
Option
Miscellaneous Selections Three
1
Mains Frequency (off = 50Hz, on = 60Hz)
2
EOL Tamper Alarm on Zone Short
3
EOL Tamper Alarm on Zone Open
4
Enable DD 243:2002 Options
5
Enable Confirmation After Entry Time Out
6
Momentary KEYSW
7
Automatically Omit Zone on Alarm
8
Automatically Omit Keyswitch Zone when
EOL Tampered
Option 1 - Mains Frequency
When 'OFF' the Mains frequency is set to 50Hz (UK).
If the wrong Mains Frequency is selected the panel will
indicate a power fault.
Option 2 - EOL Tamper Alarm on Zone Short
For details see page 13.
Option 3 - EOL Tamper Alarm on Zone Open
For details see page 13.
Option 4 - Enable DD 243:2002 Options
When 'ON' Opening the initial entry door disables ALL means of
confirmation throughout the protected premises.
22


. The display will show


Default
Off
Off
Off
Off
Off
Off
Off
Off
Veritas R8 Plus & Excel Installation Manual
When the Confirmation timer expires, the Intruder Alarm output will
restore, the next detector to activate will then cause the Intruder
Alarm output to re-activate and the Confirmation Timer to restart.
When the DD 243:2002 option is enabled, owing to the ability to
disable ALL of the confirmation facilities, the customer should
be advised in writing by the alarm company that ALL means of
confirmation are disabled when the initial entry door is opened.
The alarm company should then obtain written acceptance from
the customer of the disabling of the means of confirmation.
Option 5 - Enable Confirmation After Entry Time Out
When 'ON' confirmation is ONLY disabled for the duration of the Entry
Time and is RE-ENABLED once the Entry Time has expired, after
which activation of a further two zones must occur before the
Confirmation output will activate.
This option is only applicable if Miscellaneous Selection 03,
Option 4 is enabled.
Option 6 - Momentary KEYSW
When 'ON' any zone programmed as 'Keyswitch' will operate as
follows:
Changing the state of the zone i.e. closed to open or open to
closed will cause the system to set and changing the state of
the zone again i.e. closed to open or open to closed will
cause the system to unset.
If there has been an alarm activation, the next open close of
the Keyswitch will cause the system to enter Recall and the
next open close will Reset the panel and return it to Unset.
Option 7 - Automatically Omit Zone On Alarm
When 'ON' the system will prevent multiple alarms from the same
zone. It should NOT be used if selecting non-latching
communicator outputs (see page 34).
Option 8 - Automatically Omit Keyswitch Zone
When 'ON' a key switch cannot be used to unset the system if it is
tampered with.

Number of Alarm Activations (Re-arms)

From the Programming Menu, enter
like this.
Zon es
U n set
1 2 3 4 5 6 7 8
T am p er
Enter the desired number of Alarm Activations as a two digit
number (e.g. for three Activations, enter
indicate as each digit is entered. Press
will chime to confirm that the new number of Activations has been
accepted. The system will then automatically revert to the
Programming Menu.
The total number of Activations should not be less than 01.
 
