Programming the Control Panel

Programming the Time

From the Programming Menu, enter
like this.
Zon es
U n set
1 2 3 4 5 6 7 8
T am p er
Enter the current time as a 6 digit number; Hour, Hour, Minute,
Minute, Second, Second using 24 hour format (e.g. to program 7
minutes
and
3
seconds

). The display will indicate as each digit of the
new time is entered. Press
confirm the new time has been accepted. The system will then
automatically revert to the Programming Menu.

Programming the Service Timers

It is essential to program the current date (
(

) for correct operation of the service timers.
Programming the service timers (
prevented unless the current date (
programmed.
The user can turn off chime globally or on individual zones
but where still selected it will remain at high level until
reprogrammed by an Engineer.
Disclaimer:
It is the responsibility of the Installer to obtain prior
written agreement from the Customer regarding
any use of a Service Timer. Texecom accept no
liability whatsoever for any dispute resulting from
the use of Service Timers.
The Control Panel features three service timers designed to
facilitate the convenient support of service contracts.
Any one, any two, or all three timers can be programmed for the same
or different dates. To disable a service timer simply program an invalid
or expired date. Expired service timers are automatically cleared when
an Engineer code is entered.
Service Timer One - Reminder
Service Timer One is designed to be used as a reminder. When it
expires it turns on high level chime on all eight zones the first time
the panel is set/unset.
Service Timer Two - Nuisance
Service Timer Two is designed to be used as a nuisance. When it
expires it turns on high level chime on all eight zones every time
the panel is set/unset.
Service Timer Three - Lockout
Service Timer Three is designed to be used as a lockout. When it
expires it will turn chime off and the panel will require an Engineer
Reset (see Option 1 page 21 for details on Engineer Reset).
28

. The display will look


past
2pm
(14:07:03)
. The system will chime to
 - 

) and time



,
,

) has first been


Programming Service Timer One

From the Programming Menu, enter
like this.
1 2 3 4 5 6 7 8
Enter Service Timer One (Reminder) date as a 6 digit number;
Day, Day, Month, Month, Year, Year (e.g. to program the 1st of
enter
April 1999 enter
each digit of the new date is entered. Press
will chime to confirm the new date has been accepted. The system
will then automatically revert to the Programming.

Programming Service Timer Two

From the Programming Menu, enter
like this.
1 2 3 4 5 6 7 8
) is
Enter Service Timer Two (Nuisance) date as a 6 digit number;
Day, Day, Month, Month, Year, Year (e.g. to program the 25th of
December 2000 enter
indicate as each digit of the new date is entered. Press
The system will chime to confirm the new date has been accepted.
The system will then automatically revert to the Programming
Menu.

Programming Service Timer Three

From the Programming Menu, enter
like this.
1 2 3 4 5 6 7 8
Enter Service Timer Three (Lockout) date as a 6 digit number;
Day, Day, Month, Month, Year, Year (e.g. to program the 1st of
January 2001 enter
as each digit of the new date is entered. Press
system will chime to confirm the new date has been accepted. The
system will then automatically revert to the Programming Menu.

Programming EOL Values

This option is only available on LED keypads
From the Programming Menu, enter
10k/22k/33k operation or
. The system will chime to confirm the new value been
accepted. The system will then automatically revert to the
Programming Menu.
Veritas R8 Plus & Excel Installation Manual

Zon es

U n set

T am p er

). The display will indicate as

Zon es

U n set

T am p er


Zon es

U n set

T am p er

). The display will indicate

for 4K7/2K2 operation. Press

. The display will look
. The system

. The display will look
). The display will
.

. The display will look
. The

