Testing the Communicator Interface

From the Programming Menu, enter
indicating the current status of the eight channels will illuminate.
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) to toggle one or
more of the outputs. Press
Programming Menu. All the zone lights will illuminate.

The 250 Event Extended Log

The Control Panel incorporates a time and date stamped, non-
volatile, 250 Event Extended Log which can neither be erased nor
altered.
The 250 Event Extended Log can only be accessed using
an LCD keypad or a computer running Veritas UDL
software.
The date (see page 27) and time (see page 28) must be
programmed for the 250 Event Extended Log to function
correctly.

Viewing the Extended Log

From the Programming Menu, enter
. The display will look like this.



Use the
key to scroll up and down through the other
events.
Wherever a
symbol appears on the display, press
to display more information i.e. zone types etc.
When completed, press
Programming Menu.
INS045-14

. The zone lights


to return to the



followed by
. The system will return to the

Event Log Descriptions


Event
Code: ????????
Full Set
Part Set #?
System Unset
Zones Omitted
System Reset
Code: Anti-Code
Keypad Entry
Zone ? Open
Zone ? Shut
EOL Tamper
EOL Restore
Alarm
Keypad PA
RKP PA Restore
Lid Tamper
Lid Restore
Bell/Gbl Tamper
Bell/Gbl Restore
Code PIN Tamper
Code PIN Restore
RKP Online
RKP Offline
Mains LO
Mains OK
Volts LO
Volts OK
Line Cut
Line Restore
User Programming
Eng. Programming
Date Changed
Time Changed
SSD Change
Non-SSD Change
Defaults Loaded
Sys Check = 5
Unknown
Programming the Control Panel
Meaning
Access code entered for user ????????
The alarm system has been full set
The system has been part set using suite #?
The alarm system has been unset
Zones have been manually omitted
The alarm system has been reset
The alarm system has been reset using the
anti-code
Entry mode started using the keypad
Zone ? has been activated
Zone ? has been restored
There has been an EOL zone tamper
The EOL zone tamper has been restored
There has been an alarm activation
A keypad PA alarm has been activated
The keypad PA alarm has been restored
The panel lid has been removed
The panel lid tamper has been restored
The bell/global tamper has been activated
The bell/global tamper has been restored
Too many invalid key presses has caused a
tamper alarm
The code tamper alarm has been restored
A keypad has been recognised by the
control panel
A keypad has stopped communicating with
the control panel
The AC mains has failed
The AC mains has been restored
The battery voltage is low
The battery voltage is ok
The phone line has been removed from the
communicator
The phone line has been restored
User Programming mode was selected
Installer Programming mode was selected
The control panel date has been changed
The control panel time has been changed
Site specific data has been changed
Non site specific data has been changed
The factory default values have been loaded
Factory set parameters
No event