Miscellaneous Options - Texecom Veritas R8 Plus Installation Manual

Hide thumbs Also See for Veritas R8 Plus:
Table of Contents

Advertisement

Quick Reference and Factory Settings

Miscellaneous Options

Option
1
Cancel Strobe with Bell
2
Keypad PA (pressing
3
Single Button Setting
4
Silent Part Set Confirmation Tone
5
EN 50131-1 Requirements
6
Time Limit Engineer Access
7
Reset Button Cancels Setting
8
Automatically Omit a Mains Fail Condition (Auto-Omit AC Off)
Option
1
Internal Sounders Only on Unset Tamper Alarm
2
Internal Sounders Only on Part Set Zone Alarm
3
Internal Sounders Only on Part Set Tamper Alarm
4
Silent Part Set (no exit tone on part set)
5
High Level Chime (chime at full volume)
6
Invert Bell Output (negative removed instead of negative applied, useful for SCBs)
7
Final Door Set (system sets 3 seconds after final door closure)
8
Unlock Engineer Code (re-loading factory settings restores default Engineer code)
Option
1
Engineer Reset on Any Alarm (see page 21)
2
Engineer Reset on Tamper Alarm (see page 21)
3
Disable User Ability to Omit Tamper
4
Code PIN Tamper (tamper alarm after 16 invalid key presses when unset)
5
Random Number Remote Reset (RNRR, see page 21)
6
Push To Set (see page 22)
7
Strobe Flash on Full Set (see page 21)
8
Invert Switched Positive Output (off = negative removed, on = negative applied)
Option
1
Mains Frequency (off = 50Hz, on = 60Hz)
2
EOL Tamper Alarm on Zone Short Circuit (S/C)
3
EOL Tamper Alarm on Zone Open Circuit (O/C)
4
Enable DD 243:2002 Options (see page 22)
5
Enable Confirmation Signal After Entry Time Out
6
Operation of a Keyswitch Zone is Momentary (Momentary KEYSW)
7
Automatically Omit Zone on Alarm
8
Automatically Omit Keyswitch Zone when EOL Tampered
Option
1
Communicator Outputs Latch until System is Reset
2
Line Monitor Input causes Tamper Alarm on Line Cut
3
Invert Communicator Outputs (off = active low, on = active high)
4
Invert Remote Reset Input (off = active if negative removed, on = active if negative applied)
5
Remote Reset Input Silences Internal Sounder during Alarm
6
Remote Reset Input Clears Engineer Reset (see page 21)
7
Silent PA
8
Enable 90 Second Abort Time Limit
6
Miscellaneous Selections Zero
and
together causes PA alarm)
Miscellaneous Selections One
Miscellaneous Selections Two
Miscellaneous Selections Three
Communicator Selections
Veritas R8 Plus & Excel Installation Manual





Factory Setting
Off
Off
On
Off
Off
Off
On
Off
Factory Setting
On
On
On
Off
Off
Off
Off
On
Factory Setting
Off
Off
Off
Off
Off
Off
On
Off
Factory Setting
Off
Off
Off
Off
Off
Off
Off
Off
Factory Setting
On
Off
Off
Off
Off
Off
Off
On
INS045-14