Veritas R8 Plus & Excel Installation Manual

Programming the Chime Suite

The Chime Suite defines the zones that will be automatically
included and excluded (omitted) when chime is turned on.
From the Programming Menu, enter
chime when chime is turned on will indicate (zones that won't
chime will remain off).
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new Chime Suite has been accepted. The system
will then automatically revert to the Programming Menu.
For a description of how to turn Chime on and off see the
User Guide.

Programming the Cleaner Suite

The Cleaner Suite defines the zones that will be armed/disarmed
when the panel is set/unset with a Cleaner code.
From the Programming Menu, enter
included in the Cleaner Suite will indicate (zones not included will
remain off).
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new Cleaner Suite has been accepted. The system
will then automatically revert to the Programming Menu.
The Entry/Exit zone which the cleaner will use MUST be
included in the Cleaner Suite.
For a description of programming the Access Codes and
Access Levels (see page 32).

Programming the Double Knock Suite

The Double Knock Suite defines the zones that will be assigned
the double knock attribute
From the Programming Menu, enter
included in the Double Knock Suite will indicate (zones not
included will remain off).
Z on es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm the new Double Knock Suite has been accepted. The
system will automatically revert to the Programming Menu.
A zone should be assigned a double knock attribute when
maximum false alarm protection is required. A zone with a
double knock attribute must be activated either twice within
10 seconds or once for longer than 10 seconds in order to
cause an alarm.
Double knock is not recommended for Entry/Exit zones.
Double knock will not operate with Push to Set or Keyswitch
zones.
INS045-14

. The zones that will


. The system will chime to

. The zones currently


. The system will chime to

. The zones currently


. The system will chime to
Double knock should NOT be used for Fire, Panic, or

Tamper zones.

Programming the Manual Omit Suite

The Manual Omit Suite defines the zones that may be manually
omitted by the user.
From the Programming Menu, enter
included in the Manual Omit Suite will indicate (zones not included
will remain off).
1 2 3 4 5 6 7 8
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new Manual Omit Suite has been accepted. The
system will then automatically revert to the Programming Menu.
To prevent the user from omitting 24 Hour zones (Fire, PA

and Tamper) these would be excluded from the Manual
Omit Suite.
Zones not included in the Manual Omit Suite will still be
omitted if they are excluded in the Full or Part Set Suites.

Programming the Zone Invert Suite

The Zone Invert Suite defines the zones that are normally open
(N/O) rather than normally closed (N/C).
From the Programming Menu, enter
included in the Zone Invert Suite will indicate (zones not included
will remain off).
1 2 3 4 5 6 7 8
Press the appropriate numbered button(s) of the zone(s) to be
included or excluded. Press
confirm that the new Zone Invert Suite has been accepted. The
system will then automatically revert to the Programming Menu.

Most detectors are normally closed (N/C).
The most common normally open (N/O) sensor is a
pressure pad or push to set button.
Programming the Control Panel

Zones

Unset

Tamper
. The system will chime to

Z on es

U n set
T am p er

. The system will chime to

. The zones currently

. The zones currently
31