Programming the Control Panel

Programming the SW+ Output

From the Programming Menu, enter
the option currently selected.
Zon es
U n set
1 2 3 4 5 6 7 8
T am p er
Press the number of the function required from the following
list. Press
.
The system will chime to confirm the new function has been
accepted. The system will automatically revert to the Programming
Menu.
Option
1
Set Positive (latching detectors)
2
Alarm Positive with Latching Sensor Reset
(FTA detectors)
3
Latching Shock Sensor Auto-Reset
(old style latching shock sensors)
4
Tamper
5
Mains Fail
6
Set Positive with Latching Sensor Reset
(latching detectors)
7
Walk Test
8
Entry/Exit
If connecting multiple detectors to one zone then:
Latching detectors will indicate which detector(s) activated
during an alarm.
First to Alarm (FTA) detectors will indicate which detector
caused an alarm and which detectors were then activated
during the alarm.
Option 3 would typically be used with older designs of latching
shock sensor which do not have a Latch input and must be
powered down to clear the Latch indication. In this case the
detectors would be powered from the SW+ output.
If selecting one of the options which incorporate latching
sensor reset (2, 3 or 6) the user can force a latching sensor
reset, to clear the Latch/FTA indication, by entering their
code and pressing
The SW+ output can only sink (not source) current. If
powering detectors from the SW+ output, connect the
detector +Ve to AUX+ and the detector -Ve to SW+. It may
be necessary to invert the SW+ polarity (see page 21).
24


. The display will show


SW+ Function
.

Configuring Remote Keypads

When the system is powered up it automatically checks and
configures all connected keypads. It is strongly recommended that
the system is completely powered down (mains and battery)
before wiring a keypad. If a keypad is added without removing
power then it must be configured as described below.
From the Programming Menu, enter
the zone numbers corresponding to remote keypads (RKPs) that
are currently configured and on-line, while flashing the zone
numbers corresponding to RKPs that are currently configured but
off-line.
Zon es
1 2 3 4 5 6 7 8
To update the configuration, press
will scan for RKP addresses 1 to 6. As each RKP is detected the
control panel will configure it as present and show the zone
number corresponding to its address.
To leave configuring, press
been updated the panel will sound an error tone. The system will
automatically revert to the Programming Menu.
NEVER set two RKPs to the same address. Setting the
address of an RKP is described in the remote keypad
instructions. If an RKP is configured but off-line the system
will have a tamper fault. ALWAYS power down the control
panel when wiring a remote keypad (RKP).