Appendix C: System Specifications
Power Supply
SYS-110D-4C/8C/14C/16C/20C-FRAN8TP: PWS-804P-1R, 800W AC Redundant Power Supplies with PMBus; 80 Plus
Platinum Level Certified
Output Voltages:
750 W: 100 to 127 Vac
800 W: 200 to 240 Vac
800 W: 230 to 240 Vdc
Input Currents:
750 W: 100 to 127 Vac, 10 A
800 W: 200 to 240 Vac, 5.5 A
800 W: 230 to 240 Vdc, 5.5 A
+5 V standby: 4 A max, 0 A min
+12 V: 62.5 A max, 0.5A min (100 to 127 Vac); 66.6 A max, 0.5 A min (200 to 240 Vac, 230 to 240 Vdc)
SYS-110D-4C/8C/14C/16C/20C-FRDN8TP: PWS-601D-1R, 600 W DC Redundant Power Supplies with PMBus
Output Voltage:
600 W: -44 Vdc to -65 Vdc
Input Current:
600 W: -44 Vdc to -65 Vdc, 18-10 A
+5 V standby: 3 A max, 0 A min
+12 V: 50 A max, 0 A min
Operating Environment
Operating Environment
Operating Temperature: 0 ºC to 40 ºC (32 ºF to 104 ºF)
Non-operating Temperature: -40 ºC to 70 ºC (-104 ºF to 158 ºF)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance