SuperServer
®
SYS-111C-NR
USER'S MANUAL
Revision 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro SuperServer SYS-111C-NR

  • Page 1 SuperServer ® SYS-111C-NR USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
  • Page 4: Table Of Contents

    Contents Contents Contacting Supermicro ......................9 Chapter 1 Introduction 1.1 Overview ..........................10 1.2 System Features ........................11 Front View .........................11 Drive Carrier Indicators ....................11 Control Panel .........................12 Rear View ..........................13 Power Supply Indicator ....................14 Expansion Slots and Riser Cards .................14 LAN Speed Indicator .....................14 1.3 System Architecture ......................15...
  • Page 5 Contents 2.5 Installing the Server into a Rack ..................26 Installing the Chassis into a Telco Rack ................27 Chapter 3 Maintenance and Component Installation 3.1 Removing Power .......................28 3.2 Accessing the System ......................29 3.3 Processor and Heatsink Installation ...................30 The 4th Generation Intel Xeon Scalable Processor ............30 Creating the Processor Carrier Assembly .................31 Assembling the Processor Heatsink Module ..............32 Preparing the CPU Socket for Installation ................33...
  • Page 6 Contents 3.9 PCI Expansion Slots ......................49 Expansion Slots and Riser Cards .................49 Installing Expansion Cards ....................50 Chapter 4 Motherboard Connections 4.1 Power Connection ......................51 4.2 Headers and Connectors ....................52 Control Panel .........................55 Front Control Panel LEDs ....................55 4.3 Input/Output Ports ......................58 4.4 Jumpers ..........................60 4.5 LED Indicators ........................62 Chapter 5 Software...
  • Page 7 7.9 Where to Get Replacement Components ................82 7.10 Reporting an Issue ......................82 Technical Support Procedures ..................82 Returning Merchandise for Service ...................82 Vendor Support Filing System ..................83 7.11 Feedback ..........................83 7.12 Contacting Supermicro ......................84 Appendix A Standardized Warning Statements for AC Systems Appendix B System Specifications...
  • Page 8 Contents...
  • Page 9: Contacting Supermicro

    San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 10: Chapter 1 Introduction

    1U rackmount; (WxHxD) 17.2” x 1.7” x 23.5” (437 x 43 x 597mm) A link to the Quick Reference Guide can be found on the SYS-111C-NR of the Supermicro website. The following safety models associated with the SYS-111C-NR have been certified as...
  • Page 11: System Features

    Chapter 1: Introduction 1.2 System Features The following views of the system display the main features. Refer to Appendix B for additional specifications. Front View Service USB Ports Figure 1-1. Front View Logical Storage Drive Numbers Item Description 0 - 9 Ten 2.5"...
  • Page 12: Control Panel

    Chapter 1: Introduction Control Panel Information LED NIC LEDs Power LED UID Button/LED Power BMC Reset Figure 1-2. Control Panel Control Panel Features Feature Description The unit identification (UID) button turns on or off the blue light function of the Information UID button/LED LED and a blue LED on the rear of the chassis.
  • Page 13: Rear View

    Chapter 1: Introduction Rear View USB 3.2 Ports PWS1 PWS2 COM Port UID LED/BMC Reset BMC LAN Port Figure 1-3. System: Rear View System Features: Rear Feature Description Power Supplies Dual redundant power supply modules, PWS1 on the left, PWS2 on the right PCIe 5.0 x16 AIOM slot PCIe 5.0 x16 FHHL expansion slot PCIe 5.0 x16 AIOM slot...
  • Page 14: Power Supply Indicator

    Chapter 1: Introduction Power Supply Indicator LEDs on the power supplies indicate the status of the module. Power Supply Indicators Power Supply Condition Green LED Amber LED No Power to Power Supply Power Supply critical events causing a shutdown/ failure/ OCP/ OVP/ Fan Fail/ Amber LED OTP/ UVP Power Supply Warning Events Where the...
  • Page 15: System Architecture

    Chapter 1: Introduction 1.3 System Architecture This section shows the locations of the main system components. Rear DIMM Slots Processor System Fans Storage Backplane Front Figure 1-5. System: Top View System Features: Top Feature Description Storage Backplane Backplane for HDDs DIMM Slots 16 DIMM slots.
  • Page 16: Motherboard Layout

    Chapter 1: Introduction 1.4 Motherboard Layout Below is a layout of the X13SEDW-F motherboard with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4 or the Motherboard...
  • Page 17: Quick Reference Table

    Chapter 1: Introduction Quick Reference Table Jumper Description Default Setting JBT1 CMOS Clear Open (Normal) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) Pins 1-2 UID (Default) JRU1 Front Control Board (JFP1) Signal Reset Pins 2-3 Reset Description Status Power LED LED On: Onboard Power On LED1 BMC Heartbeat LED Blinking Green: BMC Normal...
  • Page 18 RUIO1, RUIO2 Right LUIO PCIe 5.0 x16 USB0/1 USB 2.0 Headers VGA Port Note: For detailed instructions on how to configure Network Interface Card (NIC) settings, refer to the Network Interface Card Configuration User's Guide posted on the webpage http:// www.supermicro.com/support/manuals/.
  • Page 19: Motherboard Block Diagram

    Chapter 1: Introduction Motherboard Block Diagram PCIe 5.0 x16 PCIe 5.0 x16 PE1[0-15] PE0[0-15] LUIO2 RUIO2 LANE REVERSAL PCIe 5.0 x8 PE2[8-15] JAIOM1 LANE REVERSAL PCIe 5.0 x8 PCIe 5.0 x4 MCIO x8 PE2[0-7] PE4[0-3] MCIO x4 JNVME5 JPCIE1 LANE REVERSAL PCIe 5.0 x4 PE4[4-7] MCIO x4...
  • Page 20: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 3 for details on installing those specific components.
  • Page 21: Rack Precautions

    Chapter 2: Server Installation • This product is not suitable for use with visual display workplace devices according to §2 of the German Ordinance for Work with Visual Display Units. Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them.
  • Page 22: Airflow

    Chapter 2: Server Installation Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
  • Page 23: Installing The Rails

    Chapter 2: Server Installation 2.4 Installing the Rails This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure differs slightly.
  • Page 24: Assembling The Outer Rails

    Chapter 2: Server Installation Assembling the Outer Rails Each outer rail comes in two sections that must be assembled before mounting onto the rack. Assembling the Outer Rails 1. Identify the left and right outer rails by examining the ends, which bend outward. Match the left front outer rail with the left rear outer rail and the same for the right rails.
  • Page 25: Installing The Outer Rails Onto The Rack

    Chapter 2: Server Installation Installing the Outer Rails onto the Rack Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes. If you have an older rack with round holes, these brackets must be removed, and you must use screws to secure the rail to the rack.
  • Page 26: Installing The Server Into A Rack

    Chapter 2: Server Installation Warning: Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over. 2.5 Installing the Server into a Rack You should now have rails attached to both the chassis and the rack.
  • Page 27: Installing The Chassis Into A Telco Rack

    Chapter 2: Server Installation Installing the Chassis into a Telco Rack To install the chassis into a Telco or post-style rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack.
  • Page 28: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 29: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System The CSE-LB16TS chassis features a removable top cover, which allows easy access to the inside of the chassis. Begin by removing power as described in the previous section. Removing the Top Cover 1.
  • Page 30: Processor And Heatsink Installation

    Thermal grease is pre-applied on a new heatsink. No additional thermal grease is needed. • Refer to the Supermicro website for updates on processor support. • All graphics in this manual are for illustration purposes only. Your components may look different.
  • Page 31: Creating The Processor Carrier Assembly

    Chapter 3: Maintenance and Component Installation Creating the Processor Carrier Assembly To install a processor into the processor carrier, follow the steps below: 1. Before installation, make sure the lever on the processor carrier is pressed down as shown below. 2.
  • Page 32: Assembling The Processor Heatsink Module

    Chapter 3: Maintenance and Component Installation Assembling the Processor Heatsink Module After creating the processor carrier assembly for the processor, mount it onto the heatsink to create the processor heatsink module (PHM): 1. Note the label on top of the heatsink, which marks the airflow direction. Turn the heatsink over and orient the heatsink so the airflow arrow is pointing towards the triangle on the processor.
  • Page 33: Preparing The Cpu Socket For Installation

    Chapter 3: Maintenance and Component Installation Preparing the CPU Socket for Installation This motherboard comes with a plastic protective cover installed on the CPU socket. Remove it from the socket to install the Processor Heatsink Module (PHM). Gently pull up one corner of the plastic protective cover to remove it.
  • Page 34: Install The Phm

    Chapter 3: Maintenance and Component Installation Install the PHM After assembling the Processor Heatsink Module (PHM), you are ready to install it into the CPU socket. 1. Locate four threaded fasteners (a, b, c, d) on the CPU socket. (a, b, c, d: Threaded Fasteners) CPU Socket Pin1 2.
  • Page 35 Chapter 3: Maintenance and Component Installation 4. Align peek nut "A" (next to the trianglular pin 1 on the heatsink) with threaded fastener "a" on the CPU socket. Then align peek nuts "B", "C", "D" on the heatsink with threaded fasteners "b", "c", "d"...
  • Page 36: Remove The Phm From The Motherboard

    Chapter 3: Maintenance and Component Installation Remove the PHM from the Motherboard Before removing the PHM from the motherboard, first shut down the system and unplug the AC power cord from all power supplies. 1. Use a T30-bit screwdriver to loosen the four peek nuts on the heatsink in the sequence of A, B, C, and D.
  • Page 37: Memory

    Chapter 3: Maintenance and Component Installation 3.4 Memory Memory Support The X13SEDW-F motherboard has 16 DIMM slots. It supports up to 4TB of ECC RDIMM and RDIMM 3DS DDR5 memory with speeds of up to 4800MT/s (DDR5-4400MT/s when fully populated) in 16 memory slots. Refer to the table below for the recommended DIMM population order.
  • Page 38: Guidelines Regarding Mixing Dimms

    Chapter 3: Maintenance and Component Installation Guidelines Regarding Mixing DIMMs • It is recommended to use DDR5 memory of the same type, size, and speed. • Mixed DIMM speeds can be installed. However, all DIMMs will run at the speed of the slowest DIMM.
  • Page 39 Chapter 3: Maintenance and Component Installation Compatible and Incompatible DIMM Types in a Channel and a System DIMM Type RDIMM RDIMM 3DS 9x4 RDIMM RDIMM Compatible Incompatible Incompatible RDIMM 3DS Incompatible Compatible Incompatible 9x4 RDIMM Incompatible Incompatible Compatible DDR5 Memory Support Speed (MT/s);...
  • Page 40: Installing Memory

    Chapter 3: Maintenance and Component Installation Installing Memory ESD Precautions Electrostatic Discharge (ESD) can damage electronic com ponents including memory modules. To avoid damaging DIMM modules, it is important to handle them carefully. The following measures are generally sufficient. • Use a grounded wrist strap designed to prevent static discharge.
  • Page 41: Motherboard Battery

    Chapter 3: Maintenance and Component Installation 3.5 Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system.
  • Page 42: Storage Drives

    The system supports ten hot-swap 2.5" hybrid storage drive bays. The drives are mounted in drive carriers that simplify their removal from the chassis. These carriers also help promote proper airflow. Note: Enterprise level drives are recommended for use in Supermicro servers. Installing Drives Figure 3-5. Logical Drive Numbers Removing Drive Carriers from the Chassis 1.
  • Page 43: Mounting A Drive In A Drive Carrier

    Chapter 3: Maintenance and Component Installation Mounting a Drive in a Drive Carrier 1. To add a new drive, install it into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier. 2.
  • Page 44: Drive Carrier Indicators

    Chapter 3: Maintenance and Component Installation Drive Carrier Indicators Each drive carrier has two LED indicators: an activity indicator and a status indicator. Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Blue Solid On Idle SAS drive installed Activity Blue Blinking...
  • Page 45: System Cooling

    Chapter 3: Maintenance and Component Installation 3.7 System Cooling Fans The chassis contains six 4-cm high-performance fans. Each fan unit is made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and works to dampen vibration levels. Make sure the chassis top cover makes a good seal so air circulates properly through the chassis.
  • Page 46 5. Push the fan up from the bottom and out of the top of the housing. 6. Replace the failed fan with an identical fan, available from Supermicro. Push the new fan into the housing, making sure the air flow direction is the same.
  • Page 47: Air Shrouds

    Chapter 3: Maintenance and Component Installation Air Shrouds Air shrouds concentrate airflow to maximize cooling efficiency. Installing the Standard Air Shrouds 1. Screw the guide pins into the sled as shown below. 2. Position the air shrouds and drop them onto the guide pins and into place. Figure 3-10.
  • Page 48: Power Supply

    • Solid Amber: When illuminated, indicates that the power supply is plugged in, and is in an abnormal state. The system might need service. Please contact Supermicro technical support. Changing the Power Supply Module: 1. Determine which of the two modules has failed and unplug its AC power cord.
  • Page 49: Pci Expansion Slots

    Chapter 3: Maintenance and Component Installation 3.9 PCI Expansion Slots The system offers options for riser cards that provide custom PCIe capabilities. Figure 3-12. Expansion Card Chassis Slots Expansion Slots and Riser Cards This system offers options for riser cards that provide custom PCIe 5.0 capabilities. PCIe Riser Cards Position* Part Number...
  • Page 50: Installing Expansion Cards

    Chapter 3: Maintenance and Component Installation Installing Expansion Cards (Figure on next page) 1. Use the control panel to power down the computing node, and pull the node drawer out of the chassis. 2. Open the PCI slot clip in the rear of the node drawer and remove the PCI slot shield. 3.
  • Page 51: Chapter 4 Motherboard Connections

    Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations may be found in Chapter 1.
  • Page 52: Headers And Connectors

    Chapter 4: Motherboard Connections 4.2 Headers and Connectors Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened. Refer to the table below for pin definitions.
  • Page 53 Chapter 4: Motherboard Connections M.2 Slots This motherboard has two M.2 slots (JM2_1, JM2_2). M.2 was formerly known as Next Generation Form Factor (NGFF) and serves to replace mini PCIe. M.2 allows for a variety of card sizes, increased functionality, and spatial efficiency. The M.2 connectors on the motherboard supports PCIe 3.0 from PCH in the 2280 and 22110 form factors.
  • Page 54 A Trusted Platform Module (TPM)/Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection. Use this header to enhance system performance and data security. Refer to the table below for pin definitions. Visit the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf. Trusted Platform Module Header Pin Definitions...
  • Page 55: Control Panel

    JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifically for use with a Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators.
  • Page 56 Chapter 4: Motherboard Connections Information LED (OH/Fan Fail/PWR Fail/UID LED) The Information LED (OH/Fan Fail/PWR Fail/UID LED) connection is located on pins 7 and 8 of JF1. The LED on pin 7 is active when the UID switch on the rear I/O panel is pressed. The LED on pin 8 provides warnings of overheat, power failure, or fan failure.
  • Page 57 Chapter 4: Motherboard Connections Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below for pin definitions. Power LED Pin Definitions (JF1) Pins Definition +3.3V Stby PWR LED NMI Button The non-maskable interrupt button header is located on pins 19 and 20 of JF1.
  • Page 58: Input/Output Ports

    Chapter 4: Motherboard Connections 4.3 Input/Output Ports See the figure below for the locations and descriptions of the I/O ports on the rear of the motherboard. Figure 4-1. Rear I/O Ports Rear I/O Ports Description Description AIOM2 USB3 COM1 BMC LAN AIOM1 USB2 COM Port...
  • Page 59 Chapter 4: Motherboard Connections Universal Serial Bus (USB) Ports The motherboard has two USB 2.0 headers (USB0/1), and two USB 3.2 Gen 1 ports (USB2/3) on the I/O back panel. The onboard headers can be used to provide front side USB access with a cable (not included).
  • Page 60: Jumpers

    Chapter 4: Motherboard Connections 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 61 Chapter 4: Motherboard Connections ME Manufacturing Mode Close pins 2-3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the manufacturing mode, which will allow you to flash the system firmware from a host server for system setting modifications.
  • Page 62: Led Indicators

    Chapter 4: Motherboard Connections 4.5 LED Indicators Onboard Power LED LED1 is the onboard Power LED. When this LED is on, the system is on. Turn off the system and unplug the power cord before removing or installing components. Refer to the table below for more information.
  • Page 63: Chapter 5 Software

    1. Create a method to access the MS Windows installation ISO file. That might be a USB flash or media drive, or the BMC KVM console. 2. Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 64 Chapter 5: Software 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 5-2.
  • Page 65: Driver Installation

    The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl/driver. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash or media drive.
  • Page 66: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 67: Bmc

    There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at: www.supermicro.com/en/solutions/management-software/bmc-resources BMC ADMIN User Password For security, each system is assigned a unique default BMC password for the ADMIN user.
  • Page 68: Chapter 6 Optional Components

    The JTPM1 header is used to connect a Trusted Platform Module (TPM). A TPM is a security device that supports encryption and authentication in hard drives. It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Details and installation procedures are at: http://www.supermicro.com/manuals/other/TPM.pdf. • AOM-TPM-9670V...
  • Page 69: Chapter 7 Troubleshooting And Support

    Chapter 7 Troubleshooting and Support 7.1 Information Resources Website A great deal of information is available on the Supermicro website, supermicro.com. Figure 7-1. Supermicro Website • Specifications for servers and other hardware are available by clicking the Products option. •...
  • Page 70: Bmc Interface

    Security Center for recent security notices Supermicro Phone and Addresses 7.2 BMC Interface The system supports a Baseboard Management Controller (BMC) interface. It provides remote access, monitoring and management. There are several BIOS settings related to the BMC.
  • Page 71: Troubleshooting Procedures

    Chapter 7: Troubleshooting and Support 7.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the Technical Support Procedures Returning Merchandise for Service sections in this chapter. Power down the system before changing any non hot-swap hardware components.
  • Page 72: No Video

    • Memory: Make sure that the memory modules are supported. Refer to the product page on our website at www.supermicro.com. Test the modules using memtest86 or a similar utility. • Storage drives: Make sure that all drives work properly. Replace if necessary.
  • Page 73 Also check the Control panel Overheat LED. • Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Refer to the Supermicro website for the minimum power requirements. •...
  • Page 74: Bios Error Post Codes

    When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to http://www.ami.com/products/.
  • Page 75: Crash Dump Using The Bmc Dashboard

    In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using the BMC Dashboard. The BMC manual is available at www.supermicro.com/manuals/ other/BMC_Users_Guide_X12_H12.pdf. Check Error Log 1.
  • Page 76: Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 77 USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use.
  • Page 78 Chapter 7: Troubleshooting and Support Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update"...
  • Page 79 Chapter 7: Troubleshooting and Support 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press <F4>...
  • Page 80 Chapter 7: Troubleshooting and Support Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC power cable from the power supply, clear CMOS, and plug the AC power cable in the power supply again to power on the system.
  • Page 81: Cmos Clear

    Chapter 7: Troubleshooting and Support 7.7 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
  • Page 82: Where To Get Replacement Components

    7.9 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: http://www.supermicro.com.
  • Page 83: Vendor Support Filing System

    For issues related to Red Hat Enterprise Linux, since it is a subscription based OS, contact your account representative. 7.11 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. To provide feedback on our manuals, please email us at techwriterteam@...
  • Page 84: Contacting Supermicro

    San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 85: Appendix A Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 86 Appendix A: Standardized Warning Statements for AC Systems Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 87 Appendix A: Standardized Warning Statements for AC Systems . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 88 Appendix A: Standardized Warning Statements for AC Systems Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 89 Appendix A: Standardized Warning Statements for AC Systems Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 90 Appendix A: Standardized Warning Statements for AC Systems Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 91 Appendix A: Standardized Warning Statements for AC Systems ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 92 Appendix A: Standardized Warning Statements for AC Systems Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 93 Appendix A: Standardized Warning Statements for AC Systems Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 94 Appendix A: Standardized Warning Statements for AC Systems Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 95 Appendix A: Standardized Warning Statements for AC Systems ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가...
  • Page 96 Appendix A: Standardized Warning Statements for AC Systems ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 97 Appendix A: Standardized Warning Statements for AC Systems Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 98 Appendix A: Standardized Warning Statements for AC Systems ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스...
  • Page 99 Appendix A: Standardized Warning Statements for AC Systems ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 100 Appendix A: Standardized Warning Statements for AC Systems Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 101 Appendix A: Standardized Warning Statements for AC Systems Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 102 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 103 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 104 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 105: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors Single 4th Gen Intel Xeon Scalable processor, P+ (LGA4189) sockets; up to 300W TDP (350W with conditions) Chipset Intel PCH C741 BIOS AMI BIOS; ACPI 3.0 or later, PCI firmware 4.0 support, BIOS rescue hot-key, SPI dual/quad speed support, RTC (Real Time Clock) wakeup, and SMBIOS 3.0 or later Memory 16 DIMM slots that support up to 4TB DDR5 RDIMM to 4800MT/s...
  • Page 106 Appendix B: System Specifications Regulatory Compliance FCC, ICES, CE, UKCA, VCCI, RCM, NRTL, CB Certified Safety Models Compliant with UL or CSA: LB16-8, LB16CDC-R8X13, LB16-12, LB16CDC-R12X13 Applied Directives, Standards EMC/EMI: 2014/30/EU (EMC Directive) CLASS A Electromagnetic Compatibility Regulations 2016 FCC Part 15 Subpart B ICES-003 VCCI-CISPR 32, CISPR35 AS/NZS CISPR 32, CISPR35...