Interrupting/Terminating Operation; During Breaks In Paving (E.g. Delay Due To Material Trucks); During Longer Breaks (E.g. Lunch Break) - Fayat Group DYNAPAC F1800W Operation & Maintenance Manual

Paver finisher
Table of Contents

Advertisement

1.6

Interrupting/terminating operation

During breaks in paving (e.g. delay due to material trucks)

- Determine the approximate duration.
- When cooling down of the material below the minimum paving temperature
must be expected, run the paver finisher empty and create an edge like the end of
a layer.
- Set the drive lever (1) to the centre position.
During longer breaks
(e.g. lunch break)
- Set the drive lever (1) to the centre position and the speed adjuster (2) to minimum.
- Switch the screed heater system off.
- Switch off the ignition.
- If the screed is optionally operated with a gas heater system, close the bottle valve.
The screed must be heated up to the correct paving temperature before paving may
A
be restarted.
D 42.18 25