Ultrasonic Auger Limit Switches (Left And Right) - Plc Version - Fayat Group DYNAPAC F1800W Operation & Maintenance Manual

Paver finisher
Table of Contents

Advertisement

Ultrasonic auger limit switches
(left and right) - PLC version
The limit switches control the material
A
flow at the relevant half of the auger
without contact.
The ultrasonic sensor (1) is secured to
the side shield via a bracket (2).
- To adjust, release the clamping lever /
stop screw (3) and adjust the sensor's
angle.
- After adjusting, retighten all mounting
parts properly.
The connection cables (4) are connected to the relevant sockets on the remote con-
A
trol bracket.
The sensors should be adjusted so that 2/3 of the augers are covered with the
A
paving material.
The paving material must be conveyed over the full working width.
A
We recommend adjusting the limit switch positions during material distribution.
A
In vehicles with a PLC control system, the deactivation point is set on the
A
remote control.
D 30.18 24