Before starting work
(in the morning or when starting paving)
- Heed the safety instructions.
- Check the personal protective equipment .
- Take an inspection walk around the paver finisher and check for leaks
and damages.
- Install parts removed for transportation or for the night.
- When screed is operated with the optional gas heating system, open the closing
valves and the main shut-off valve.
- Perform the check according to the following "Checklist for the machine operator".

Check list for the machine operator

Check!
Emergency stop button
- on the operating panel
- on both remote controls
Steering
Horn
- On the operating panel
- on both remote controls
Lights
Screed hazard flasher
(with vario screeds)
Gas heater system (o):
- Bottle holder
- Bottle valve
- Pressure reducer
- Hose rupture protection
- Closing valve
- Main shut-off valve
- Connections
- Indicator lamps of the switch box
How?
Push in the button.
The diesel engine and all running drives
must stop immediately.
The paver finisher must immediately fol-
low every steering wheel movement in a
precise manner. Check straight ahead
travel.
Briefly press the horn button.
Horn signal must sound.
Switch on with the ignition key, walk
around the paver finisher to check and
switch off again.
With the ignition switched on, press the
switches for extending/retracting the
screed parts.
The rear lights must flash.
Check:
- Secure seat
- Cleanliness and tightness
- Working pressure 1.5 bar
- Function
- Function
- Function
- Tightness
- All indicator lamps must light up when
the system is switched on
D 42.18 3