TURNING OFF MACHINE
1. Turn the machine off by pressing the
2. The
symbol on the display will start blinking.
3. Push the
button a second time and the pump will stop immediately.
4. If no action is taken the pump turns off after 4 seconds.
5. Close the cover and the machine will initiate the cool-down phase and perform a number of vacuum cycles
while the cover stays closed and the machine will turn off automatically after about 15 minutes.
- These cycles are necessary to cool down the machine and to allow any moisture in the oil of the pump to
evaporate.
TEN-PROGRAM CONTROL SYSTEM
The ten-program control system is standard time-based on the M20, M40-M80, L01-L60.
- Sensor-based operation is an option, which can be installed at a later date.
The ten-program control system provides:
- 9 customizable programs (P1-P9).
- Program PA; this is an - automatic program – pre-set at the factory at a vacuum time of 30-40 seconds (or
5 mbar for a sensor-based program) and a sealing time of 2 seconds.
Program P H2O for liquid products.
- When turning on the machine, the pump will start. After about 15 minutes of inactivity, the pump will stop
automatically.
PROGRAMMABLE FUNCTIONS
The following functions may be customized for each program P1-P9:
Vacuum time: in seconds or mbar (only with sensor).
Sealing time: in seconds.
Vacuum plus: on/off, in seconds.
Gassing: on/off, in seconds or mbar (only with sensor).
Clean cut controlled (CCC) seal: on/off, in seconds.
Soft-air: on/off, in seconds or mbar (only with sensor).
Multi-cycle: on/off, in number of cycles.
REVIEWING FUNCTION VALUES FOR P1-P9
1. Turn the machine on by pushing the
2. The most-recently used program will be indicated.
3. All selected functions for this program are indicated at the bottom of the display.
4. To review the values for these functions, push the
function value.
5. The values cannot be changed; this can only be done in the settings menu.
6. Push the
button to return to the home menu.
PROGRAMMING AND ADjUSTING VALUES FOR P1-P9
1. Select the program to be set up or adjusted.
button.
button.
button; use the
13