Operation
When operating a packaging machine with a sensor-based program, the actual vacuum pressure is digitally
shown on the LCD display in mbar (standard setting) or in % vacuum.
PLUG AND PLAY
When turning on a sensor-based machine for the first time, it will start up in the PA program AUTOMATIC.
This is a pre-set factory program with 5 mbar of vacuum and 2 seconds of sealing time.
When turning on the machine after that, it will start up in the most-recently used program.
OPTIONAL INSTALLATION OF SOFT-AIR
The soft-air feature can also be installed at a later date by ordering the optional soft-air kit.
OPERATING THE MACHINE WITH TEN-PROGRAM CONTROL SYSTEM
On: turns the machine on:
The machine will start up in the most-recently used program.
The pump of a machine with a transparent cover will start when the cover is closed.
Off: turns the machine off:
When pressing the
after about 4 seconds.
When pressing the
Closing the cover will initiate the cool-down phase.
The machine will complete a number of vacuum cycles before turning off automatically.
Stop-function:
Stops the machine at any point in the cycle and aerates the chamber.
Reset-function:
While programming, resets the program value to its original setting.
Press the menu button
Back function:
While reviewing programmed values, returns to the previous selection.
Stops the active function and initiates the next step in the cycle:
While the machine is running, exits the active function and jumps to the next step in the cycle.
While packing sauce or soup, the package may be sealed as soon as product boiling is
detected.
Menu button:
Toggles between home menu
Save function: during programming, confirms and saves the entered program values and
returns to the home menu.
Return function: returns to the home menu.
review program values:
Displays the programmed value for each function; the function being reviewed will be
blinking.
Returns to the home menu.
button once, the
button a second time, the pump will stop immediately.
to return to the home menu.
Cycles through programs P1 to P9, as well as PA and P H2O.
Displays the value for the next function.
symbol will start blinking and the pump will stop
and settings menu