IS 6.1
6 MAINTENANCE
GB
6.1 P
REAMBLE
It is recommended to strictly follow the instructions
in the manual provided by the engine manufacturer,
which accompanies each generator.
It is impo rtant to regularly c heck and carry o ut
maintenance on the generator. The operations to carry
out must be decided on the basis of the hours of
operation.
In order to carry out maintenance, the side and top doors
must be removed.
The generator is started from a remote control
panel.In order to prevent any accidental starting, set
the emergency switch to the 0 (OFF) position.
Disconnect the negative pole from the starter battery.
Any maintenance operation on the generator must
be carried out with the engine off, after leaving it to
cool down sufficiently.
Carefully read paragraph 1.5 "General danger
information" in the manual. Periodically check the
electrical safety switches, such as the emergency
button, the earthing system, etc.
6.2 R
E
OUTINE
NGINE
The periodic operations to be carried out on the engine
are indicated in the table "Serv ice schedule" in
paragraph 6.18.
For more detailed information, consult the manual
provided by the engine manufacturer, which is provided
with each generator.
GB
- 34
M
AINTENANCE
6.3 E
O
C
NGINE
IL
HECK
- Check the oil level by means of the cap/dipstick (ref.1).
The oil level must always be between the MAX and MIN
notches engraved on the dipstick.
- When checking the oil level, ensure that the generator
is positioned horizontally.