PROGRAMMING

- In order to access programming mode, press the
summer/winter Button (3) for 4 seconds.
0
3
The display will flash while waiting for the password to be
entered.
There are 3 different levels:
- Installer
- Factory
- Monitor

6 1 Installer Level

- Access programming mode by pressing the summer/
winter Button (3) for 4 seconds
- Press the "+" and "-" heating Buttons (2) to enter the
Installer password "03"
- Press the summer/winter Button (3) once to confirm
0
2
3
If the password is incorrect, the system will return to stand-
ard mode.
The installer level has been accessed, the user will be able
to view and modify certain parameters. The first digit will
display a letter followed by the parameter number.
- Press the "+" and "-" heating Buttons (2) to scroll
through the parameters
P
2
00
Fig. 52
03
Fig. 53
0 I
Fig. 54
The selected parameter number will appear in alternation
with the set value. The value assigned to the selected pa-
rameter is shown in the two digits on the right.
- Press the "+" and "-" domestic hot water Buttons (4) to
modify the parameter's value until the desired value
is obtained
The new value will begin to flash
P
2
3
- Press the summer/winter Button (3) to confirm, or else
the"+" and "-" heating Buttons (2) to cancel

6 2 Factory Level

Everything is the same as in the previous case, but with a
factory password that allows the user to access the pro-
tected parameters.

6 3 Monitor Level

The Monitor level allows the user to view the values as-
signed to the probes one at a time (see the table below).
- Press the summer/winter Button (3) for 4 seconds
- Press the summer/winter Button (3) again
i
2
3
The first value, which corresponds to the delivery tempera-
ture, will appear on the display.
- Press of the "+" and "-" heating Buttons (2) to scroll
through all the available values
Displayed values
CH flow temperature
Return temperature
Domestic hot water temperature
Outdoor sensor temperature
Flue gas temperature
2nd circuit temperature
Fan speed
Ionization
55
4
Fig. 55
60
Fig. 56
Digit 1
Digit 2-3
1
Value
2
Value
3
Value
4
Value
5
Value
6
Value
7
Value
Range
8
70-100
75