Pump - Beretta POWER X 50 DEP Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

Product efficiency characteristics:
Description
Maximum rated heat input
Minimum rated heat input
Domestic hot water maximum rated thermal input (80-
60)
Domestic hot water minimum rated thermal input (80-
60)
Parameter
Seasonal heating energy efficiency class
Rated input
Seasonal energy efficiency in central heating mode
useful heat output
at rated thermal input and at high temperature rating
at 30% of rated thermal input and at low temperature
rating
Efficiency
at rated thermal input and at high temperature rating
at 30% of rated thermal input and at low temperature
rating
Auxiliary electric consumption
at full load
at partial load
in stand-by
Other parameters
Heat losses in standby
Annual energy consumption
Level of inner sound power
Emissions of nitrogen oxides
For combined heating appliances
Declared load profile

2 7 Pump

The boilers POWER X come equipped with high-efficiency
modulating circulators, with the electrical and water con-
nections already complete.
Thanks to the new electronic circuit board installed on the
boiler, this circulator is capable of operating in both modu-
lating and fixed mode, with the latter offering three speeds:
- fixed mode at low speed
- fixed mode at normal speed
- fixed mode at maximum speed.
By default, the unit is set to operate in modulating mode. In
this case, when activated by the system, the pump starts
at maximum speed, and modulates after 1 minute until the
required ΔT target has been reached.
The boiler is equipped with an anti-blocking system, which
activates an operating cycle after every 24 hours of disuse,
regardless of the mode selector's position.
b
The "anti-blocking" function is only enabled if the boil-
ers are receiving electrical power.
b
It is strictly forbidden to operate the circulator without
water.
b
A minimum flow rate of 800l/h must be guaranteed
within the boiler in order to prevent the differential
pressure switch from being triggered.
POWER X
35 R.S.I.
50 DEP R.S.I.
35
38,6
5,8
15
A
A
31,5
34,1
92,8
92,4
30,9
34,1
11,4
12,6
88
88
98
97
88
77
38
24
2
2
400
341
66
72,8
53
58,2
35
38,5
The curve of the head available for the system, depending
on the water flow rate, is shown below (the boiler's load
losses have already been calculated).
The indicated flow rates refer to the range of possible spe-
cies.
In fact, the modulating circulator can adjust the speed in
order to obtain a constant temperature difference between
the delivery and return lines, as well as to always obtain the
maximum efficiency.
7
6
5
4
3
2
1
0
0,0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2,0 2,2
System flow rate m
50 / 50 R.S.I.
50
kW
15
kW
kW
kW
A
-
44,2
kW
92,5
%
44,2
kW
16,3
kW
88
%
98
%
80
W
24
W
2
W
442
W
94,2
GJ
58,2
dB
38,5
mg/kWh
/h
3
Fig. 7
49