System Specifications

System Specifications
Table 19 System specifications
a
Transfer relay rating (A
)
Transfer time (milliseconds
   Shore to inverter:
   Inverter to shore:
Transfer voltage (V)
   Shore to inverter:
   Inverter to shore:
Cooling
a
 Circuit breakers shall not carry more than 80% of their UL current rating continuously.
b
 To change the AC Transfer time (mode), see Adjusting Settings in Configuration Mode on page 51.
86
30A (24A continuous)
b
)
<20 milliseconds
<20 milliseconds with a 20-second delay
<85 V and >140 V
<135 V and >90 V
Fan, activated by any of the following:
   High internal temperature
   High AC output power
Freedom XC 1000