Figure 25: Displaying PoE System Power
Use the PoE > PD Alive page to configure periodic checking of connected PoE
powered devices.
Parameters
These parameters are displayed:
Port — Selects a port number.
PD Alive Check — Enables the periodic checking of connected powered
devices to determine their alive status. (Default: Disabled for all ports)
PD IP Address — The IPv4 address of the connected device.
Interval Time — The time between each PD alive check. (Range: 10-300
seconds)
Retry Count — The number of times a PD alive check is sent to a device
before the device is reported as down. (Range: 1-5 times)
PD Boot Time — The wait time before a device is restarted. (Range: 60-300
seconds)
Web Interface
To configure PD Alive checking:
1.
Click PoE, then PD Alive.
2.
Select the port that you want to configure or modify.
3.
Set PD Alive Check to enable for the port.
4.
Enter the PD IP Address, Interval Time, Retry Count, and PD Boot Time.
5.
Click Apply.
– 43 –
Chapter 6
| PoE Configuration
PD Alive