Setting The Time Using Sntp - Edimax ECS1100 Series Web Management Manual

Table of Contents

Advertisement

Setting the Time
Use the System Management > System Time page to set the system time on the
Using SNTP
switch using SNTP.
Parameters
The following parameters are displayed:
Web Interface
To set the time using SNTP:
1.
2.
3.
4.
5.
Figure 8: Manually Setting the System Time
Time Mode Setting — Selects "manual" or "sntp" for setting the time.
(Default: manual)
Current System Time — Shows the current time set on the switch.
SNTP Master Server — Sets the IPv4 address for the primary time server.
SNTP Slave Server — Sets the IPv4 address for the secondary time server. The
switch attempts to update the time from the primary server, if this fails it attempts
an update from the secondary server.
Timezone — To display a time corresponding to your local time, you must
indicate the number of hours and minutes your time zone is east (before) or
west (after) of UTC (Coordinated Universal Time or UTC, formerly Greenwich
Mean Time). A drop-down box provides access to predefined time zone
configurations. Each choice indicates it's offset from UTC and lists at least one
major city or location covered by the time zone.
Click System Management, then System Time.
Select "sntp" as the mode.
Enter IPv4 addresses for the master and slave SNTP servers.
Select your local time zone from the list.
Click Apply
– 19 –