Fujitsu AJ 126LELDH Series Design & Technical Manual page 591

Hide thumbs Also See for AJ 126LELDH Series:
Table of Contents

Advertisement

• Pattern B
1. Use a tool to cut off the terminal on the end of the remote controller cable, and then remove
the insulation from the cut end of the cable as shown below.
2. Connect the remote controller cable and connecting cable as shown below. Be sure to insu-
late the connection between the cables.
3. Connect the remote controller cable to the connecting cable, and insert it to the connector.
Set the DIP switch (SW1) to "3WIRE" on the PCB of the indoor unit.
NOTE: Layout of terminal block and PCB is varies depending on the type of indoor unit.
¢ Specifications
Dimensions (H × W × D)
Weight
 Wiring specifications
Use
Remote controller
cable
2-13. Simple remote controller (Without operation mode: UTY-RHK)
Insulated
connection
Remote
controller cable
Set to "3WIRE" the
DIP switch (SW1)
Connect to earth
Functional grounding
(ground) screw
(If necessary)
Remote controller
Connecting cable
cable
Connector
(adapter)
mm
g
Cable size
2
0.33 mm
(22 AWG)
- (05-91) -
20 mm
Remote
controller cable
White
Connecting
cable
Red
Black
Indoor unit
PCB
Connector CNC01
(onboard)
SW1
Indoor unit
PCB
120 × 75 × 14
Wire type
Polar 3-core
90
Remarks
Use sheathed PVC cable.
2. Control units

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents