Fujitsu AirStage AG A007GCGH Series Operating Manual
Fujitsu AirStage AG A007GCGH Series Operating Manual

Fujitsu AirStage AG A007GCGH Series Operating Manual

Hide thumbs Also See for AirStage AG A007GCGH Series:

Advertisement

Quick Links

EEV internal model
AG*A004GCGH
AG*A007GCGH
AG*A009GCGH
AG*A012GCGH
AG*A014GCGH
EEV external model
AG*E004GCEH
AG*E007GCEH
AG*E009GCEH
AG*E012GCEH
AG*E014GCEH
OPERATING MANUAL
INDOOR UNIT (Floor type)
Keep this manual for future reference.
BEDIENUNGSANLEITUNG
INNENGERÄT (Fußbodentyp)
Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf.
MODE D'EMPLOI
UNITÉ INTÉRIEURE (Type sol)
Conservez ce manuel pour pour toute référence ultérieure.
MANUAL DE FUNCIONAMIENTO
UNIDAD INTERIOR (Tipo suelo)
Conserve este manual para posibles consultas futuras.
MANUALE DI ISTRUZIONI
UNITÀ INTERNA (Tipo da pavimento)
Conservare questo manuale per consultazione futura.
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (Τύπος δαπέδου)
Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά.
MANUAL DE FUNCIONAMENTO
UNIDADE INTERIOR (Tipo de chão)
Guarde este manual para consulta futura.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
ВНУТРЕННИЙ МОДУЛЬ (Напольный тип)
Сохраните данное руководство для последующего использования.
KULLANIM KILAVUZU
Bu kılavuzu ileride başvurmak üzere saklayın.
Refer to the rating label with the serial number.
İÇ ÜNİTE (Yer tipi)
MADE IN P.R.C.
[Original instructions]
PART No. 9382567057

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AirStage AG A007GCGH Series

  • Page 1 OPERATING MANUAL INDOOR UNIT (Floor type) Keep this manual for future reference. BEDIENUNGSANLEITUNG INNENGERÄT (Fußbodentyp) Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf. MODE D’EMPLOI UNITÉ INTÉRIEURE (Type sol) Conservez ce manuel pour pour toute référence ultérieure. EEV internal model MANUAL DE FUNCIONAMIENTO AG*A004GCGH AG*A007GCGH...
  • Page 2: Table Of Contents

    OPERATING MANUAL ● Do not operate the air conditioner with wet hands. ● Check the condition of the installation stand for damage. PART No. 9382567057 VRF system indoor unit (Floor type) ● Operate only with air fi lters installed. ● Do not drink the water drained from the air conditioner. CONTENTS ●...
  • Page 3: Manual Auto Operation

    (9) Intake grille Horizontal airfl ow direction (10) Front panel (11) Air fi lter The horizontal airfl ow direction can be manually set by adjusting horizon- (12) Vertical airfl ow direction louver tal airfl ow direction louvers. (13) Horizontal airfl ow direction louver (behind the Vertical airfl ow direc- tion louver and the Damper) (14) Damper (15) Air cleaning fi...
  • Page 4: Operating Tips

    OPERATING TIPS ● If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit Operation and Performance is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other About priority state and standby state damage.
  • Page 5 3. Replace the Intake grille. Air cleaning fi lter installation (1) Hook the ropes. 1. Open the Intake grille and remove the Air fi lters. (2) Set the left and right mounting shafts into the bearings at the bottom of the panel. (3) Press the place where the mark on the diagram indicates and close the Intake grille.
  • Page 6: Troubleshooting

    3. Install the two Air fi lters and close the Intake grille. TROUBLESHOOTING The following conditions are not breakdowns or op- eration failures. Doesn’t operate immediately: ● If the unit is stopped and then immediately started again, the com- pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
  • Page 7: Specifications

    The following conditions may not be breakdowns so SPECIFICATIONS check again. Doesn’t operate at all: AG*A004 AG*A007 AG*A009 AG*A012 AG*A014 MODEL ● Has there been a power failure? GCGH GCGH GCGH GCGH GCGH ● Has a fuse blown out, or a circuit breaker been tripped? POWER SOURCE 220-240V ~ 50Hz, 230V ~ 60Hz ●...

Table of Contents