Fujitsu AIRSTAGE ARXC036GTEH Installation Manual
Fujitsu AIRSTAGE ARXC036GTEH Installation Manual

Fujitsu AIRSTAGE ARXC036GTEH Installation Manual

Indoor unit duct type
Hide thumbs Also See for AIRSTAGE ARXC036GTEH:

Advertisement

Quick Links

ARXC036GTEH
Refer to the rating label for the serial number,
manufactured year and month.
TM
INSTALLATION MANUAL
INSTALLATIONSANLEITUNG
MANUEL D'INSTALLATION
MANUAL DE INSTALACIÓN
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ (Τύπος Αγωγού)
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
UNIDADE INTERIOR (Tipo de tubagem)
РУКОВОДСТВО ПО УСТАНОВКЕ
Только для авторизованного обслуживающего персонала.
INDOOR UNIT (Duct Type)
For authorized service personnel only.
INNENGERÄT (Kanaltyp)
Nur für autorisiertes Fachpersonal.
UNITÉ INTÉRIEURE (type conduit)
Pour le personnel agréé uniquement.
UNIDAD INTERIOR (Tipo conducto)
UNITÀ INTERNA (tipo a condotto)
Apenas para técnicos autorizados.
ВНУТРЕННИЙ МОДУЛЬ (Короб)
MONTAJ KILAVUZU
İÇ ÜNİTE (Kanal Tipi)
Yalnızca yetkili servis personeli için.
MADE IN THAILAND
[Original instructions]
PART No. 9373870258

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AIRSTAGE ARXC036GTEH

  • Page 1 INSTALLATION MANUAL INDOOR UNIT (Duct Type) For authorized service personnel only. INSTALLATIONSANLEITUNG INNENGERÄT (Kanaltyp) Nur für autorisiertes Fachpersonal. MANUEL D’INSTALLATION UNITÉ INTÉRIEURE (type conduit) Pour le personnel agréé uniquement. MANUAL DE INSTALACIÓN ARXC036GTEH UNIDAD INTERIOR (Tipo conducto) Únicamente para personal de servicio autorizado. MANUALE DI INSTALLAZIONE UNITÀ...
  • Page 2: Table Of Contents

    INSTALLATION MANUAL This mark indicates procedures which, if improperly performed, CAUTION might possibly result in personal harm to the user, or damage to PART No. 9373870258 property. VRF system indoor unit (Duct type) Read carefully all security information before use or install the air conditioner. Contents Do not attempt to install the air conditioner or a part of the air conditioner by yourself.
  • Page 3: Accessories

    2.3. Accessories 2.4. Optional parts The following options are available. WARNING Description Model Application For installation purposes, be sure to use the parts supplied by the manufacturer or For output function other prescribed parts. The use of non-prescribed parts can cause serious accidents UTY-XWZXZC (Output terminal / CNB01) such as the unit falling, water leakage, electric shock, or fi...
  • Page 4: Installation Dimension

    3.2. Installation dimension CAUTION Fasten the unit securely with special nuts A and B. Install at least 20 mm from the ceiling. 3.3.2. Leveling Use the procedure in the following fi gure to adjust the levelness. Level Provide a service access for inspection purposes as shown below. Do not place any wiring or illumination in the service space, as they will impede service.
  • Page 5: Pipe Installation

    Check if [L] is fl ared uniformly and 4. PIPE INSTALLATION is not cracked or scratched. CAUTION Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with refrigerant R410A models. Also, when storing the piping, securely seal the openings Pipe by pinching, taping, etc.
  • Page 6: Installing Heat Insulation

    Applying 4.4. Installing heat insulation area of Joint pipe Hard PVC side adhesive Install the coupler heat insulation after completing the refrigerant leak check (for details, (locally purchased) refer to the Installation Manual for the outdoor unit). Drain pipe (VP25) Coupler heat (locally purchased) insulation...
  • Page 7: Electrical Wiring

    PROHIBITED CAUTION Earth (Ground) the unit. Rise Do not connect the earth (ground) cable to a gas pipe, water pipe, lightning rod, or a telephone earth (ground) cable. Improper earthing (grounding) may cause electric shock. Air bleeding Do not connect power supply cables to the transmission or remote controller terminals, as this will damage the product.
  • Page 8: Wiring Method

    B. For strand wiring 6.2. Wiring method (1) Use ring terminals with insulating sleeves as shown in the fi gure below to connect to the terminal block. Example (2) Securely clamp the ring terminals to the cables using an appropriate tool so that the Outdoor unit or RB unit *1 cables do not come loose.
  • Page 9: Connection Of Wiring

    Name Application 6.4. Connection of wiring Power indicator Indicates the state of the power supply. Refer to “Power indicator (1) Remove the control box cover and install each connection cable. lamp (green) lamp status” following. CNA01 Apply voltage terminal For external input CNA03 CNA02 Dry contact terminal...
  • Page 10: External Input And External Output (Optional Parts)

    When connected to Dry contact terminals of multiple indoor units with a connected unit, 6.6. External input and external output (Optional parts) insulate each indoor unit with relay, etc. as shown on below example. (1) External input • Indoor unit can be Operation/Stop, Emergency stop or Forced stop by using indoor unit P.C.B PCB CNA01 or CNA02.
  • Page 11: Remote Sensor (Optional Parts)

    [In the case of “Pulse” input] 6.7. Remote sensor (Optional parts) Connector Input signal Command • For the installation method, please refer to the INSTALLATION MANUAL of remote sensor. OFF → ON Forced stop CNA01 or CNA02 OFF → ON Normal Connection methods •...
  • Page 12: Custom Code Setting

    • If working in an environ- Table A 7.4. Function setting ment where the wireless Rotary switch Rotary switch remote controller can be Address Address setting setting • FUNCTION SETTING can be performed with the wired or wireless remote controller. used, the addresses can (The remote controller is optional equipment) also be set using the...
  • Page 13: Test Run

    Function 10. ERROR CODES Function Setting number Default Details number 00 0°C If you use a wired type remote controller, error codes will appear on the remote controller 01 0.5°C display. If you use a wireless remote controller, the lamp on the photodetector unit will 02 1.0°C output error codes by way of blinking patterns.