Fujitsu AJ 126LELDH Series Design & Technical Manual page 526

Hide thumbs Also See for AJ 126LELDH Series:
Table of Contents

Advertisement

¢ Functions
Item
Indoor unit registration
Installation
Function settings
Display switching
Display units
Monitor contents (icon display)
Monitor
Monitor contents (list display)
Error list
Special state
Control units
Control contents
Detailed control contents
Control
Individual setting reset of airflow direc-
tion
Human sensor
Setting temperature limitation of room
Language setting*
Date and time
Time zone
Panel cleaning and correction
Group
Back ground light and beep sound
Password
Schedule timer
Temperature range
Network
Setting
Low noise operation
Electricity charge apportionment (Op-
tion)
Remote language additional registra-
tion
Auto OFF timer
Set temperature auto return
Display item setting
Failure notification Email
Remote connection setting
Error history
Status history
Maintenance
Operation history
TPC information
Others
External input/output
NOTES:
• *: Product specifications are subject to change without notice.
• When Start/Stop, operation mode setting, room temp. setting, fan speed setting, air flow direction setting, swing setting, economy mode, and anti freeze setting are changed frequently
by using the central controller such as System controller, Touch panel controller, etc. or from Building Management System (BMS) via BACnet gateway or via Network converter, the
number of operations for each indoor unit must not exceed 7,500 times/year.
If the number of setting change exceeds the above specified number, the rewriting count limit of the non-volatile memory (built into the air conditioner and used for recording settings)
will be exceeded, and may cause breakdown.
2-3. Touch panel controller (UTY-DTGZ1)
Main unit
PC/Tablet
Indoor unit registration. Max. 400 units. (Set data can be written to and read from USB flash
drive)
Temperature set point limitation, external input, central operation on/off setting
Icon display, List display
All, Group, Individual (remote control group)
Group name, operation, operation mode, set temperature, time, errors, timer setting, filter sign
Group name, operation, operation mode, set temperature, airflow, air direction, special opera-
tion, anti-freeze, time, errors, timer setting, filter sign, room temp., human sensor, set temp.
range
Group name, remote control group name, address, error code
Display during special operation
All, Group, Individual (remote control group)
Operation, operation mode, set temperature, airflow, RC prohibition, filter sign reset
Air direction, energy saving, anti-freeze, test run
Sets the position of indoor unit's airflow direction louver individually.
Sets the human sensor on the indoor unit.
Adjusts the upper and lower limits of temperature for the indoor unit.
Design considering multi-language correspondence
Time display switching, year/month/day display switching, system clock setting, summer time,
Internet time adjustment setting
Set the time zone of the area where this unit is used.
Select display area for panel cleaning. User can select black screen on display.
Stages: Max. 3 stages settable up to 400 groups. (Set data can be written to and read from
USB flash drive.)
Backlighting off time and brightness setting, beep sound operation setting
Management level: 3 kinds
Max. 30 items settable
Celsius/Fahrenheit switching, cooling, heating, and AUTO each settable
Function of Email notification for malfunction, or electricity charge apportionment option is used
via LAN
"Low noise operation" is set to all outdoor units registered by this controller.
Start/stop of ECA, importing/exporting of ECA setting, and exporting ECA data.
Additional language can be integrated on remote device by creating language database.
Additional language is displayed on only the remote device and touch panel controller cannot
be added other language.
Function to stop the operation automatically when a preset time lapses after turning on the op-
eration
Function to restore the temperature to the original set temperature when a preset time lapses
after changing the set temperature.
Sets the items to be displayed on the monitor.
Failure notification Email: Sends a notification Email to the preset Email address in the event of
failure.
Create Users: Max. 15 users, type, permissions, unit setting, automatic logout time
Recording of max. 10 errors for each touch panel controller and each indoor and outdoor unit
Recording of max. 100 operations for each indoor unit
Writable to USB flash drive
Recording of max. 10,000 operations
Writable to USB flash drive
Version history, TPC MAC address, software version, Writing the TPC information
Input: Batch operation/stop, emergency stop, electricity meter
Output: Operation monitoring, error