¢ Software configuration
(VRF network system side)
• Any number can be installed in remote site personal computers.
– System controller (UTY-APGXZ1) can be installed in the local site PCs (VRF controller) con-
nected to the VRF network system.
– Multiple remote site PCs (VRF explorer) can be connected to VRF controller via Internet or LAN.
Just this single product creates the control, management, and monitoring environment for the cus-
tomer's properties including remote operation.
NOTES:
• WHITE-USB-KEY is not required for PCs on the remote site.
• Some function, such as equipment registration and input/output are invalid on the remote site.
• Optional software to strengthen the energy saving function
Installing the optional UTY-PEGXZ1 will strengthen the energy saving management function.
¢ Other required devices (Locally purchased)
• Personal computer that satisfies the following system requirements
Operating system
CPU
Memory
HDD
Display
Interface
Graphic accelerator
Software
• Echelon U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for
each VRF network)
2-1. System controller (UTY-APGXZ1)
VRF Controller
WHITE-USB-KEY
WHITE-USB-KEY
UTY-PEGXZ1, UTY-PPGXP2
Local Site
Personal computer system requirement
Microsoft Windows 7 Home Premium (32-bit or 64-bit) SP1
Microsoft Windows 7 Professional (32-bit or 64-bit) SP1
Microsoft Windows 8.1 (32-bit or 64-bit)
Microsoft Windows 8.1 Pro (32-bit or 64-bit)
Microsoft Windows 10 Home (32-bit or 64-bit)
Microsoft Windows 10 Pro (32-bit or 64-bit)
Supported languages: English, Chinese, French, German, Russian, Spanish, and
Polish
Intel Core i3 2 GHz or higher
2 GB or more (for Windows 7 [32-bit])
4 GB or more (for Windows 7 [64-bit], Windows 8.1, and Windows 10)
40 GB or more of free space
1,024 × 768 or higher resolution
Ethernet port (for getting access to the Internet using LAN) or Modem (for
getting access to the Internet using public telephone line)
USB ports (Maximum of 5 ports) (Required only for the server PC that works
as VRF controller)
Maximum of 1 USB ports are required for WHITE-USB-KEY connection
Maximum of 4 USB ports are required for Echelon U10 USB Network
Interface
NOTE: Maximum number of required USB ports depends on the
applicable system configuration.
Microsoft DirectX 9.0c compatible
Adobe Reader 9.0 or later
- (05-17) -
VRF Explorer
UTY-APGXZ1
WHITE-USB-KEY
unnecessary
Remote Site
Option
(Monitoring center side)
2. Control units