Type Plates - WAGNER Cobra 40-10 Translation Of The Original Operating Manual

High-pressure double diaphragm pumps
Table of Contents

Advertisement

Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
3   Identification
Electrostatic surface spraying
4 Do not spray device parts using electrostatic equipment.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
4 Remove deposits from the surfaces to maintain conductivity.
4 Use only a damp cloth to clean the device.
Air in the pump fluid
Ignitable gas mixtures can form if air enters the pump fluid.
4 Prevent the pump from taking in air and running dry.
4 If air has been taken in, fix the leak. Then, fill slowly and in a controlled manner until the
air has escaped.
Air in the pumped liquid can be caused by damaged diaphragms.
4 Avoid operating the pump with damaged diaphragms.
4 Periodically check that the pump is working smoothly, paying special attention to the
presence of air in the pumped fluid.
Filling and emptying
Ignitable gas mixtures can form in the fluid section or product hoses if the pump must be
emptied for maintenance and/or repair purposes.
4 Empty and fill the device slowly and in a controlled manner.
4 Avoid potentially explosive atmosphere in the surroundings.
3.3   TYPE PLATES
1
Patents: https://go.wagner-group.com/patents
2
Pumpentyp/ Pump type/ Type de pompe
3
Max. Materialdruck/ Fluid pressure/ Pression fluid
4
Übersetzungsverhältnis/ Ratio/ Rapport
5
Fördermenge DH/ Delivery DS/ Débit CD
6
Max. Luftdruck/ Air pressure/ Pression d`air
7
Max. Temp. Material/ Fluid
8
Baujahr - Serie Nr. / Year of manufacture - Serial No.
9
Vor Gebrauch Betriebsanleitung beachten / Check manual before use!
10
B_05038
Example type plate Cobra 40-10
1
Manufacturer and identification
2
Link to the list of patents
3
Pump type
4
Maximum product pressure
5
Pump ratio
12
Wagner International AG
CH-9450 Altstätten
II 2 G Ex h IIB T6 Gb X
Made in Switzerland
6
7
8
9
10 Read operating manual before use!
40-10
25 MPa
40:1
10 ccm
0.6 MPa
80°C
2021-0001
Flow rate per double stroke
Maximum air inlet pressure
Maximum product temperature
Model year - serial number
Order number 2340851 | Edition 05/2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cobra 40-25

Table of Contents