8   Cleaning and Maintenance
Hose imprinting
WAGNER
yymm
xxx bar (xx MPa) e.g. 270 bar (27MPa)
XX
DNxx (e.g., DN10)
8.2.6   Emptying Pump
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ignition of potentially explosive surrounding atmosphere.
4 Empty and fill the device slowly and in a controlled manner.
4 Avoid potentially explosive atmosphere in the surroundings.
Info
If the pumping product becomes heated, switch off all heaters and let the product cool
off.
B_04240
1. Visual check: personal safety equipment, grounding and all devices ready to use.
2. Place an empty, grounded collection tank (5) under the return tube (4).
3. Place the suction hose (7) in an empty, grounded tank (6).
4. Close pressure regulator (1) (0 MPa; 0 bar; 0 psi).
Emptying via return line
1. Open the relief valve (3).
44
Meaning
Name / manufacturer
Date of manufacture (year/month)
Pressure
Internal code
Nominal diameter
1
2
3
9
4
6
5
7
Order number 2340851 | Edition 05/2022