WAGNER Cobra 40-10 Translation Of The Original Operating Manual page 23

High-pressure double diaphragm pumps
Table of Contents

Advertisement

Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
5   Description
Description
Weight
Product pH value
Maximum product pressure at pump inlet
Product temperature
Ambient temperature - Assembly and operation
Ambient temperature - Storage
Relative humidity
Allowable inclination for operation
Hydraulic oil filling amount (approximate)
* Measured A-rated emission sound pressure level at distance of 1 m, LpA1m in accordance
with DIN EN 14462: 2015. Reference measurements have been made by Suva (Swiss National
Accident Insurance Fund).
WARNING
Exhaust air containing oil!
Risk of poisoning if inhaled.
4 Provide compressed air free from oil and water.
Order number 2340851 | Edition 05/2022
Units
Cobra
40-10
kg; lb
19; 41.9
pH
3.5 – 9
MPa
2
bar
20
psi
290
°C
10 – 80
°F
50 – 176
°C
10 – 60
°F
50 – 140
°C
-20 – 60
°F
-4 – 140
%
10–95 (without conden-
sation)
∠°
± 10
L
0.110
cu inch
6.71
Cobra
40-25
33; 72.8
0.130
7.93
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cobra 40-25

Table of Contents