8.2.17 Output Low Limit Setting (Function G-2)

The low limit of the current output for converter can be set.
The output low limit can be selected from the items listed in the table below.
● Output low limit setting function
Selection items
4.0mA
3.2mA
2.4mA
Note: If the low cutoff value in 8.2.12 "Low Cutoff" is set to a value other than 0%, the output low
limit value will be fixed to 4.0mA, regardless of the set value.
Display example
ALM 4-20
UNDER 3mA
ESC
ALM 4-20
UNDER 3mA
ALM 4-20
4mA
ALM 4-20
4mA
SET OK?
ESC
O K
N O
Output low limit
The current value can be outputted up to 4.0mA (0%).
The current value can be outputted up to 3.2mA (−5%).
The current value can be outputted up to 2.4mA (−10%).
- 81 -
Description
The currently set value (UNDER 3.0mA in
this example) appears.
Then push
.
ESC
* Pushing
returns you to the setting
menu.
The switches at the bottom change.
(
At the same time, the cursor appears.
(The item indicated by the cursor is
highlighted.)
Then push
You can continue to change the setting item.
Push
to change the selection
items.
: Selected item is scrolled up.
: Selected item is scrolled down.
When the desired item is selected, push
to set the item temporarily.
When you push
, a message appears
to confirm whether the setting is OK or not.
O K
If OK, push
. If you want to redo the
N O
setting, push
.
ESC
Pushing
cancels the setting operation
and exits the setting screen.
6 F 8 A 0 9 9 7
are shown.)
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf622 b series

Table of Contents