You can check or change the output low limit as described below.
The following is an example to change the output low limit value from 4.0mA to 2.4mA.
Switch operation
STEP1
STEP2
STEP3
STEP4(=END)

Function H: Digital Output Settings

8.2.18 Digital Output (Function H)

Digital output functions can be selected.
You can select the digital output function from the tables shown below.
For details of digital output functions, see 10, "Functional Description."
Display example
G:4-20mA
Select "LOW LIM" from the setting item
1 ALM 4-20
selection menu.
2 LOW LIM
3 EXIT
ESC
LOW LIM
The currently set value (4.0mA in this
example) appears.
4.0mA
Then push
*Pushing
menu.
ESC
LOW LIM
The switches at the bottom change.
(
4.0mA
At the same time, the cursor appears.
(The item indicated by the cursor is
highlighted.)
Then push
LOW LIM
You can continue to change the setting item.
Push
2.4mA
items.
When the desired item is selected, push
LOW LIM
When you push
to confirm whether the setting is OK or not.
2.4mA
If OK, push
setting, push
SET OK?
Pushing
and exits the setting screen.
ESC
O K
N O
- 82 -
6 F 8 A 0 9 9 7
Description
.
ESC
returns you to the setting
are shown.)
.
to change the selection
: Selected item is scrolled up.
: Selected item is scrolled down.
to set the item temporarily.
, a message appears
O K
. If you want to redo the
N O
.
ESC
cancels the setting operation