Toshiba LF620 B Series Instruction Manual page 121

Electromagnetic flowmeter converter
Table of Contents

Advertisement

Totalizer Operation
●Operation using the operation switches
You can start, stop or clear the totalizer as described below.
Switch operation
CNT
*
is displayed while the totalizer is in operation and
is stopped.
* If an erroneous password is input when password is asked, or if it is a sealed
specification,
CLR
Longer
OK
Display example
PUSH SW
CNT:
CNT CTRL
SET:
SET MODE
SET
ESC
CNT
CNT CTRL
12345678
FRD
CLR
ESC
CLR
is not displayed.
CNT CTRL
12345679
FRD
CLR
ESC
CNT CTRL
12345679
FRD
CLR OK?
NO
OK
CNT CTRL
0
FRD
CLR
ESC
- 120 -
Description
Mode change screen
When you push
in the measurement
CNT
mode, the screen moves to the totalizer
control screen.
Totalized flow count (both directions)
appears automatically on this screen.
In addition, the switches
CLR
ESC
(
are shown.)
is displayed when it
When you push
, the totalizer starts
counting and
appears on the screen. In
addition,
changes to
When you push and hold
confirmation message appears.
Pushing
OK
clears the totalizer and
pushing
cancels the clear operation.
NO
Pushing
at the end returns you to the
ESC
measurement mode.
6 F 8 A 0 9 9 7
.
CLR
longer, a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lf622 b series

Table of Contents