Electrolux SkyLine PremiumS User Manual page 76

Electrical and gas oven
Table of Contents

Advertisement

Anom-
Type of
Description
aly
anomaly
nIUS
Warning
NIU SW version is
incompatible with UI
Stops only
N°E161
SW version.
connectiv-
ity
nIUH
Warning
NIU unknown
N°E162
Stops only
connectiv-
ity
nIUC
Warning
NIU configuration not
valid
N°E163
Stops only
connectiv-
ity
nIUP
Warning
No valid PNC and SN
found
N°E164
Stops only
connectiv-
ity
PCE1
Stops oven
Wrong Parameter con-
figuration: Appliance
N°125
with boiler but without
lambda probe
PdEF
Stops oven
Memorized default
parameters corrupted
PFOr
One or more Factory
parameters are out of
N°123
range
PUOr
One or more User
parameters are out of
N°122
range
PUSr
The User parameters
calculated is different
N°120
to the stored one
PFAC
Stops oven
Factory parameters
map corrupted
N°121
rtc1
Warning
The communication
between the RTC and
N°111
HACCP
the microcontroller is
will not
blocked
function
SbbU
Stops
Boiler gas fan speed
boiler gas
issue
N°306
SbCd
Stops
Cavity lower gas
cycle
burner blower speed
N°305
issue
SbCU
Stops
Cavity upper gas
cycle/
burner blower speed
N°304
convection
issue
76
Possible causes
Once the NIU has been
installed, it has been recog-
nized an incompatible
software version of the NIU
-
-
Physical memory failure
One or more Factory
parameter are out of range
One or more User parame-
ters are out of range
Invalid data on User
parameters
Issue with the SW or with
the HW.
• Burner blower motor
overload due to dirt or
oxidation;
• Other electrical/mechani-
cal issue.
• Burner blower motor
overload due to dirt or
oxidation;
• Other electrical/mechani-
cal issue.
• Burner blower motor
overload due to dirt or
oxidation;
• Other electrical/mechani-
cal issue.
Actions
• Call service
-
-
Wrong Parameter configuration: Appliance with
boiler but without lambda probe.
Parameters memory corrupted;
• Try to switch the oven OFF/ON.
• If the problem persists, call service.
• Call service
• Call service
• Call service
• Try to switch the oven OFF/ON.
• If the problem persists, call Service.
Communication impossible with internal clock.
• Call service
Burner fan does not reach the desired speed.
Call Service.
Burner fan does not reach desired speed.
• Call service
Burner fan does not reach desired speed.
Ovens with boiler can cook in 100℃ steam mode.
To restore full oven functionality call Service.