Electrolux SkyLine PremiumS User Manual page 71

Electrical and gas oven
Table of Contents

Advertisement

Anom-
Type of
Description
aly
anomaly
CSHt
Warning
Cavity SSR NTC high
temperature (NTC3)
N°312
CSOt
Stops
Cavity SSR NTC over-
cooking
temperature (NTC3)
N°311
cycle
dESC
Warning
Descale Boiler
N°230
Boiler thermocouple
EbOL
Stops
cycle/
failure
N°222
preheating
EbYP
Warning
Steam exhaust tem-
perature sensor failure.
N°250
Bottom cavity thermo-
ECEd
Stops
couple failure
cycle
N°213
ECEu
Stops
Upper cavity thermo-
cycle
couple failure
N°212
ECLt
Stops oven
Cleaning table not
present for the
N°135
MODEL and the
DETERGENT TYPE in
use
EGA0
Stops oven
No one valid GAS
table present in the
N°130
oven
EGAd
Stops oven
Wrong GAS table data
N°132
EGAt
Stops oven
GAS table for this
appliance model not
N°131
found
EH2O
Stops oven
Water measured
inconsistent with
N°327
valves state
Possible causes
• Inlet air filter dirty;
• Cooling fan failure,
• Cooling inlet air sucking
warm/hot air;
• Oven installed by hot
machine;
• Steam/Heat leakage in
the electronic
compartment;
• Inlet air filter dirty;
• Cooling fan failure;
• Cooling inlet air sucking
warm/hot air;
• Oven installed by hot
machine;
• Steam/Heat leakage in
the electronic
compartment;
Parameter bSCt has been
reached.
• Connector failure;
• TC sensor failure;
• ACU failure.
• Connector failure;
• TC sensor failure;
• ACU failure.
• Connector failure;
• TC sensor failure;
• ACU failure.
• Connector failure;
• TC sensor failure;
• ACU failure.
Software missing
Software missing
Software missing
Software missing
• Water supply valve
closed or partly closed;
• Temporary lack of water
supply pressure;
• Flow meter failure;
• Water system issue.
Actions
• Do not switch the oven Off;
• Wait for the temperature to decrease;
• Clean the inlet air filter;
• Check with a thin strip of paper whether a
consistent air flow can be detected at the
cooling air inlet: if not, call Service;
• Check if the inlet cooling air may be affected
by heat produced in the kitchen (in case the
oven is located by hot appliances, stop work-
ing with those appliances and inform Service);
• If the error persists, call Service.
The oven can continue to work in recovery
mode: cooking cycles will not use the boiler.
• Do not switch the oven OFF;
• Wait for the temperature to decrease;
• Clean the inlet air filter;
• Check with a thin strip of paper whether a
consistent air flow can be detected at the
cooling air inlet: if not, call service;
• Check if the inlet cooling air may be affected
by heat produced in the kitchen (in case the
oven is located by hot appliances, stop work-
ing with those appliances and inform Service);
• If the error persists, call Service.
Run a cleaning program including the rinse and
descale cycle and use 2 tabs C25 only for 6-10
grids models and 3 tabs only for 20 grids models
(follow the procedure as per Operating Manual).
The oven can continue to work without preheat-
ing (check the cooking results).
• Inform Service about the failure.
The oven can continue to work, it is possible that
water consumption increases.
Call Service.
The oven can continue to work only with 100 ℃
steam cycle.
Call Service.
The oven can continue to work only with 100 ℃
steam cycle.
Call Service.
Cleaning table not present for the MODEL and
the DETERGENT TYPE in use.
Call Service.
No one valid GAS table present in the oven.
Call Service.
Wrong GAS table data.
Call Service.
GAS table for this appliance model not found.
Call Service.
The oven can continue to work (check the cook-
ing results).
• Check if the water supply valve is open;
• Check the water pressure is > 1,5 bar;
• If the problem, persists call Service.