3 TECHNICAL DATA

3
TECHNICAL DATA
Mains voltage
Primary current I
max
MIG/MAG (GMAW)
TIG (GTAW)
MMA (SMAW)
Idle power
Setting range
MIG/MAG (GMAW)
TIG (GTAW)
MMA (SMAW)
Permissible load at MIG/MAG (GMAW)
60 % duty cycle
100% duty cycle
Permissible load at TIG (GTAW)
60 % duty cycle
100% duty cycle
Permissible load at MMA (SMAW)
60 % duty cycle at 220 VAC
60 % duty cycle
100% duty cycle
Power factor at maximum current
Efficiency at maximum current
Electrode types
Open-circuit voltage
VRD deactivated
VRD activated
Apparent power at maximum
current
Active power at maximum current
Operating temperature
Transportation temperature
Constant sound pressure when
idling
Dimensions l × w × h
Weight
0463 441 101
Warrior™ 350i MV CC/CV Warrior™ 400i MV CC/CV
208-460 V ±10%,
3~ 50/60 Hz
39 A
30 A
41 A
50 W
16 A/15 V - 350 A/32 V
5 A/10 V - 350 A/24 V
16 A/20 V - 350 A/34 V
350 A / 32 V
300 A / 29 V
350 A / 24 V
300 A / 22 V
-
350 A / 34 V
300 A / 32 V
0.95
85 %
56 V DC peak
28 V DC peak
14.7 kVA
14.0 kW
14-104 °F (-10 to +40 °C)
-4-131 °F (-20 to +55 °C)
28.03 x 12.80 x 18.50 in. (712 × 325 × 470 mm)
134 lb. (60.8 kg)
- 11 -
220-460 V ±10%,
3~ 50/60 Hz
44 A
34 A
44 A
50 W
16 A/15 V - 400 A/34 V
5 A/10 V - 400 A/26 V
16 A/20 V - 400 A/36 V
400 A/34 V
300 A/29 V
400 A/26 V
300 A/22 V
380 A/35.2 V
400 A/36 V
400 A/32 V
0.95
85 %
Basic
Rutile
Cellulosic
56 V DC peak
28 V DC peak
17.8 kVA
16.9 kW
<70 dB(A)
© ESAB AB 2022