5 OPERATION

5
OPERATION
General safety regulations for handling the equipment can be found in the "SAFETY"
chapter of this manual. Read it through before you start using the equipment!
NOTE!
When moving the equipment use intended handle. Never pull the cables.
WARNING!
Electric shock! Do not touch the workpiece or the welding head during operation!
5.1

Connections and control devices

1.
Mains power supply switch, O/I
2.
Indicator lamp, yellow, thermal
3.
Indicator lamp, green, VRD function
(reduced open-circuit voltage)
4.
Display, current (A) and voltage (V)
5.
Knob for setting: MMA/TIG Arc air
gouging: Current (A) Mobile Feed
mode: Voltage (V)
6.
Knob for choice of electrode type
7.
Knob for inductance (MIG/MAG) and
arc force (MMA):
5.2

Connection of welding and return cables

The power source has two outputs, a positive welding terminal (+) and a negative welding
terminal (-), for connecting welding and return cables. The output to which the welding cable
is connected depends on the welding method or type of electrode used.
Connect the return cable to the other output on the power source. Secure the return cable's
contact clamp to the work piece and ensure that there is good contact between the work
piece and the output for the return cable on the power source.
0463 441 101
8.
Knob for welding method
9.
Negative welding terminal
10.
Positive welding terminal
11.
Circuit breaker, 10 A, 42 V
12.
Connection of wire feed unit
13.
Connection of remote control unit (option)
14.
Connection of mains power supply