Compilation of the asset management record
You have various possibilities for compiling the asset management record for an I-device:
● Recommendation: The Siemens Industry Online Support makes an application available
to you that helps you to compile the asset management record.
The data area of the asset management record is divided in two. The first part consists of
an automatically determined area that packages the IM0 data of the slots of the I-device
into an asset management block. The second part consists of the user-specific asset
management blocks. You configure the user-specific asset management blocks based on
pre-configured asset management record structures, fill them with information and make
them available to the application.
The application performs the following:
– The application determines the required size of all the asset management blocks.
– The application fills the data block in accordance with the specifications of an asset
– The application makes this asset management record available to the higher-level
(https://support.industry.siemens.com/cs/ww/en/view/109748894)
● You create the asset management record yourself.
The following section describes how you can compile an asset management record for an
I-device yourself.
The concept assumes you yourself determine the I&M data for each centrally plugged
module and fill the asset management record with this information. The I&M0 data of a
module contains basic information about the module such as the manufacturer's code,
article number, serial number, hardware and firmware version. These are the data that
are also required in the AM record for an asset.
Determine the I&M data of centrally plugged modules
The central structure consists of an optionally plugged power supply unit (Slot 0), followed by
the I-device CPU (Slot 1), and then followed by the further modules, such as digital modules,
analog modules, etc. (as of Slot 2).
You determine the I&M data with the "Get_IM_Data" instruction for the plugged modules with
exception of the CPU:
To assign parameters for the "Get_IM_Data" instruction, you require the hardware identifier
(LADDR input parameter). You determine the hardware identifier for each occupied slot with
the "GEO2LOG" instruction (Determine hardware identifier from slot).
Summary of the theoretical steps:
1. In a loop, determine the hardware identifiers of the plugged modules with the
"GEO2LOG" instruction.
2. For each hardware identifier found, determine the I&M data by using the "Get_IM_Data"
instruction and store these data in a data block that you address with the input parameter
DATA. Use ARRAY of BYTE for the data storage. This corresponds to the description of
the AM record contents in the preceding section.
PROFINET with STEP 7 V15
Function Manual, 12/2017, A5E03444486-AH
management record with the automatically determined asset management blocks and
your user-specific asset management blocks.
IO controller.
The application is described in this application example
Diagnostics and maintenance
4.1 Diagnostics mechanisms of PROFINET IO