Error code
Name
(hex)
804D0000
BadBrowseDirectionInvalid
804E0000
BadNodeNotInView
804F0000
BadServerUriInvalid
80500000
BadServerNameMissing
80510000
BadDiscoveryUrlMissing
80520000
BadSempahoreFileMissing
80530000
BadRequestTypeInvalid
80540000
BadSecurityModeRejected
80550000
BadSecurityPolicyRejected
80560000
BadTooManySessions
80570000
BadUserSignatureInvalid
80580000
BadApplicationSignature
Invalid
80590000
BadNoValidCertificates
805A0000
BadRequestCancelled
ByRequest
805B0000
BadParentNodeIdInvalid
805C0000
BadReferenceNotAllowed
805D0000
BadNodeIdRejected
805E0000
BadNodeIdExists
805F0000
BadNodeClassInvalid
80600000
BadBrowseNameInvalid
80610000
BadBrowseNameDuplicated
80620000
BadNodeAttributesInvalid
80630000
BadTypeDefinitionInvalid
80640000
BadSourceNodeIdInvalid
80650000
BadTargetNodeIdInvalid
80660000
BadDuplicateReference
NotAllowed
80670000
BadInvalidSelfReference
80680000
BadReferenceLocalOnly
80690000
BadNoDeleteRights
806A0000
BadServerIndexInvalid
806B0000
BadViewIdUnknown
806D0000
BadTooManyMatches
806E0000
BadQueryTooComplex
806F0000
BadNoMatch
80700000
BadMaxAgeInvalid
Communication
Function Manual, 12/2017, A5E03735815-AF
Status "Bad" (8000_0000 - FFFF_FFFF)
Meaning
The browse direction is not valid.
The node is not part of the view.
The ServerUri is not a valid URI.
No ServerName was specified
No DiscoveryUrl was specified.
The semaphore file specified by the client is not valid.
The security token request type is not valid.
The security mode does not meet the requirements set by the Server.
The security policy does not meet the requirements set by the Server.
The server has reached its maximum number of sessions.
The user token signature is missing or invalid.
The signature generated with the client certificate is missing or invalid.
The client did not provide at least one software certificate that is valid and
meets the profile requirements for the server.
The request was cancelled by the client with the Cancel service.
The parent node id does not to refer to a valid node.
The reference could not be created because it violates constraints imposed
by the data model.
The requested node id was reject because it was either invalid or server
does not allow node ids to be specified by the client.
The requested node id is already used by another node.
The node class is not valid.
The browse name is invalid.
The browse name is not unique among nodes that share the same relation-
ship with the parent.
The node attributes are not valid for the node class.
The type definition node id does not reference an appropriate type node.
The source node id does not reference a valid node.
The target node id does not reference a valid node.
The reference type between the nodes is already defined.
The server does not allow this type of selfreference on this node.
The reference type is not valid for a reference to a remote server.
The server will not allow the node to be deleted.
The server index is not valid.
The view id does not refer to a valid view node.
The requested operation has too many matches to return.
The requested operation requires too many resources in the server.
The requested operation has no match to return.
The max age parameter is invalid.
OPC UA communication