Programming
4.3 Time-based IO
Reaction to error
The Error output indicates if the instruction was processed correctly. The reasons for the
errors are displayed at the Status output.
Parameter
The table below shows the parameters of the TIO_DQ instruction.
Parameter
Declaration
REQ
Input
HWID*
Input
Channel*
Input
TIO_SYNC_
Input
Data*
Out_Mode
Input
TO*
Input
TimeStamp
Input
RE
TimeStampF
Input
E
StatusDQ
Output
BUSY
Output
DONE
Output
Status
Output
Error
Output
* Checked once at startup of the CPU
54
Data type
Default
S7-1500
Bool
False
HW_IO
0
UInt
0
"TIO_SYNC_
Data"
UInt
2
LTime
LT#0ns
LTime
LT#0ns
LTime
LT#0ns
Bool
False
Bool
False
Bool
False
DWord
16#0
Bool
False
Description
Starts the job at a positive edge.
Hardware identifier for TIO module from HWCN.
Number (0 ... m) of the digital output of the connected
TM Timer DIDQ
System time provided for the TIO instructions of the TIO
modules by the TIO_SYNC instruction. See UDT
"TIO_SYNC_Data" (Page 57).
Connect this input parameter with the "TIO_SYNC_Data" output
parameter of the TIO_SYNC instruction.
Specify the output mode for the edges at the digital output:
0
: Output only positive edge (TimeStampRE).
D
1
: Output only negative edge (TimeStampFE).
D
2
: Both edges are output (TimeStampRE and TimeStampFE).
D
3
: Each edge is output directly when TimeStampRE = 0 or
D
TimeStampFE = 0. If both time stamps have the value "0" or if
no time stamp has the value "0", no edge is output.
4 bis 255
: Reserved
D
T
: Time for output of isochronous output data.
o
Apply T
from the ET 200 station (properties of the PROFINET
o
interface).
Time stamp: Time when a positive edge is to be output.
Time stamp: Time when a negative edge is to be output.
Actual status of the digital output.
If an inversion of the digital output is configured, StatusDQ is
inverted as well.
BUSY = True: The job is not complete yet.
DONE = True is displayed for one cycle: The job is signaled as
"done, no errors".
Status of the instruction: see description of Status parameter
If True, this output indicates that an error has occurred. In this
case, BUSY and DONE are set to False. For detailed
information see Status parameter.
Error is reset as soon as the error is remedied.
High-precision input/output with Time-based IO