Sxt User Programming; Diagnositc Programming Mode - Pentair FLECK 2510 Service Manual

Aio control valve
Hide thumbs Also See for FLECK 2510:
Table of Contents

Advertisement

SXT USER PROGRAMMING

Programming
Programming
Abbreviation
Definition
DO
Day Override
RT
Regeneration
Time
NOTE: The timer will discard any changes and exit User
Mode if any button is not pressed for sixty seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service.
2. Use this display to adjust the Day Override. This option
setting is identified by "DO" in the upper left hand corner
of the screen.
3. Press the Extra Cycle button. Use this display to adjust
the Regeneration Time. This option setting is identified by
"RT" in the upper left hand corner of the screen.
4. Press the Extra Cycle button to end User Programming
Mode.
Default
Option Definition
Values
3
Days Between Regeneration
- In conditions of high water
usage and/or high levels of
contaminants, the AIO may
need to regenerate more
frequently than once every
three days. DO NOT set the
regeneration day override for
a longer period than three
days, as the filter media
can become fouled with
contaminates, rendering the
AIO ineffective.
12:00 AM
Regeneration Time - If there
is a need to change the
factory default, then make
sure the time of regeneration
is not the same as any other
water treatment equipment
in the system.
DIAGNOSTIC PROGRAMMING MODE
Diagnostic Programming Mode Options
Abbreviation
Parameter
HR
Hours in Service
SV
Software Version
NOTE: The timer will exit Diagnostic Mode after 60 seconds if
no buttons are pressed.
Diagnostic Programming Mode Steps
1. Press the Up and Extra Cycle buttons for five seconds while
in service.
2. Press the Up button. Use this display to view the Hours in
Service since the last regeneration cycle. This option setting
is identified by "HR" in the upper left hand corner of the
screen.
3. Press the Up button. Use this display to view the Software
Version. This option setting is identified by "SV" in the upper
left hand corner of the screen.
4. Press the Extra Cycle button to end Diagnostic
Programming Mode.
Description
Displays the total hours that the
unit has been in service
Displays the software version
installed on the controller
FLECK
2510 AIO SXT Service Manual
• 7