owner's information
Smart Thermostat (Transmitter Operation)
The smart thermostat function adjusts the flame height based on the
difference between the set point and the actual room temperatures. As
the room temperature gets closer to the set point, the smart function
will turn the flame down.
To activate this function, press the THERMOSTAT key (fig. 1) until the word
"SMART" appears to the right of the temperature bulb graphic (fig. 11).
To adjust the set temperature, press the UP or DOWN ARROW keys
until the desired temperature is displayed on the transmitter's LCD
screen (fig. 12).
• When smart thermostat is activated, manual flame height adjust-
ment is disabled.
Figure 11: Smart Flame Function
Fan Speed Control**
If the appliance is equipped with a hot air circulating fan, its speed can
be controlled by the Proflame system. To activate this function, use the
MODE key (fig.1) to scroll to the fan control icon (fig. 13). Use the UP/
DOWN ARROW keys (fig.1) to turn on, off, or adjust to one of the fan's
six speeds (fig. 14). A single "beep" confirms reception of the command.
Figure 13
On Demand Pilot Light (seven-day safety timer) (Non Power Vent Model Only)
Important information if using the appliance in CPI (continuous pilot mode) only
This appliance is a ProFlame 2 system fitted with the "On Demand" Pilot, a safety feature which will shut down the gas valve completely by extinguishing
the pilot light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the "on" position in your remote control transmitter.
Each time the main burner shuts down, manually or through the call from the thermostat, the seven-day timer starts again.
The seven-day inactivity timer is controlled within the circuit board. Therefore, if in CPI mode and when the pilot light is extinguished after seven straight
days of inactivity, the CPI setting on the remote control transmitter will remain in the "CPI" (continuous pilot) position. Therefore, all that is required to
relight the pilot would be to press the on/off button on the remote control transmitter from "on" to "off" and back to "on". Once the pilot has re-established
operation will resume as normal. There is no requirement to do anything with the IPI/CPI mode on the remote control transmitter.
If the unit never goes as long as seven full days without a call for heat, the pilot will remain lit until it is manually shutoff.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven-day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or relight the pilot.
14
| City Series CP60E
Figure 12
Figure 14
Remote Dimmer Control (Light)**
The auxiliary function controls the AUX power outlet by the dimmable
light control. To activate this function, use the MODE key (fig. 1) to scroll
to the AUX icon (fig. 15 & 16).
The intensity of the output can be adjusted through six (6) levels. Use
the UP/DOWN ARROW keys (fig.1) to adjust the output level (fig. 16). A
single "beep" confirms reception of the command.
• This function is available only with the IFC Control Module.
Figure 15
Split Flow control**
The secondary burner is controlled by the split flow. To activate this
function, use the MODE key (fig. 1) to scroll to the SPLIT FLOW mode
icon (fig. 17 & 18).
Pressing the UP ARROW key will activate the secondary burner. Pressing
the DOWN ARROW key will turn the secondary burner off. A single "beep"
confirms the reception of the command.
Figure 17
Figure 16
Figure 18