Regency City CP60E Owners & Installation Manual page 75

Table of Contents

Advertisement

Glass Barrier Adjustment
Glass barrier adjustment
If glass isn't hanging straight, use a phillips screwdriver to adjust the angle.
9. Adjust the Side A and Side B barrier glass angle to be parallel with the End barrier glass.
Clockwise = angles barrier out toward you
Counter clockwise = angles barrier in towards the unit.
Slide the screwdriver straight up at the two indicator slots.
10. Gently slide Side A and Side B barrier glass towards the End barrier glass as close as possible without touching. Edges should be parallel.
11. Make additional adjustments if required.
12. Ensure that hooks are sitting over their pins and that the glass is sitting level and centered in the opening.
13. Remove the vacuum clamps and corner protectors.
14. To remove the glass, see the owner's manual.
installation-panels, barriers, faceplates
A
3RD ANGLE
TOLERANCES UNLESS
PROJECTION
OTHERWISE STATED
DIMENSIONS
0.000 = 0.01 CRITICAL
0.000 = SPECIFIED TOLERANCE
DO NOT SCALE
0.000 = 0.031
DRAWING
0.000 REF = REFERENCE ONLY
UNITS IN INCHES
ANGULAR = 1
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CO
PARALELL EDGES
DETAIL A
SCALE 1 : 8
Glass barrier removal video
FIREPLACE PRODUCTS
INTERNATIONAL
1:24
SCALE:
11/18/2021
DWN:
DATE:
E.C.N.:
SIGN:
DATE:
City Series CP60E |
-
MAT'L :
SHEAR/ PUNCH/ FORM
PROCESS :
CP60 MAIN ASSEMBLY
PART :
PART NO:
REV
457-500
-
75