Direct Vent Gas Power Vent Fireplace
STYLE
Left Corner CC40LEPV-NG / CC40LEPV-LP
Right Corner CC40REPV-NG / CC40REPV-LP
Warning
Fire or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Certified to/Certifié pour: CSA 2.17-2017
919-925b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
City Series
MODEL
ANSI Z21.88-2017
CSA 2.33-2017
®
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
www.regency-fire.com
03.27.19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the City Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency City Series

  • Page 1 City Series ® Owners & Direct Vent Gas Power Vent Fireplace Installation Manual www.regency-fire.com STYLE MODEL Left Corner CC40LEPV-NG / CC40LEPV-LP Right Corner CC40REPV-NG / CC40REPV-LP Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The City Series are hand crafted appliances and ® have been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The CC40LE /CC40RE City Series have been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace. ® This appliance may be installed in an aftermarket, permanently lo- cated, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
  • Page 3 MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: ® VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2017 / CSA 2.33-2017 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CSA 2.17-2017. This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada. This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada. This Regency mobile/manufactured home listed appliance comes factory equipped with four 1/4" diameter holes located near each corner ® of the base. Fasten the fireplace in place using screw, inserted through the holes. This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes. See the "Wiring Diagram" section. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. This appliance may only be installed in an aftermarket permanently located, manufactured home (U.S.A only) or mobile home, where not prohibited by local codes. This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Ensure that structural members are not cut or weakened during installation. City Series CC40EPV |...
  • Page 4: Table Of Contents

    table of contents Copy of Safety Decal .............5 Vertical Flue Extension Kit (Part #946-756)....47 Important Message ............8 Ceiling Firestop / Firestop Spacer (Part #946-757) ..47 Before You Start .............8 Power Vent Terminal Installation ........48 Gas Power Vent Installation - Wiring the Power Vent to the Unit ................50 Owner's Information High Elevation ..............53 General Safety Information ..........9 Gas Line Installation ............53 Lighting Procedure ............10 Pilot Adjustment ............53 Shutdown Procedure ...........10 Gas Pipe Pressure Testing ..........53 Copy of the Lighting Plate Instructions ......11 885 S.I.T. Valve Description .........53 Proflame II Remote Control Operating Instructions ..12 Wiring Diagram ............54 Inner Glass Panel (Firebox Glass) Installation / Removal Inner Glass Panel (Firebox Glass) Installation / Removal ..................16 ..................55 Outer Safety Glass Panel (Barrier Glass) Installation /...
  • Page 5: Copy Of Safety Decal

    This is a copy of the label that accompanies Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the outer front panel is removed. NOTE: Regency units are constantly being improved. Check ® the label on the unit and if there is a difference, the label on the unit is the correct one. Copy of Safety Decal Duplicate S/N DO NOT REMOVE THIS LABEL / Listed/Nom: VENTED GAS FIREPLACE / FOYER AU GAZ À ÉVACUATION NE PAS ENLEVER CETTE ÉTIQUETTE Certified to/Certifi : é...
  • Page 6 dimensions CC40LE (Left Corner) Dimensions " 1203mm " " 616mm 587mm 4" " 102mm 172mm 48" " 1219mm 475mm " " 449mm 1109mm " " 375mm 1089mm Note: Height Dimension may vary depending on the height of the leveling legs. Dimensions will appear as (inches)" / (metric)mm throughout this manual. The inches are rounded to the nearest 1/16" when converted, when greater accuracy is required, use the metric dimensions. Note: These units are non-load bearing. ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
  • Page 7 dimensions CC40RE (Right Corner) Dimensions " 1203mm " " 587mm 616mm 4" " " 102mm 172mm 475mm " " 448mm 1108mm " 43" 374mm 1091mm Note: Height Dimension may vary depending on the height of the leveling legs. Dimensions will appear as (inches)" / (metric)mm throughout this manual. The inches are rounded to the nearest 1/16" when converted, when greater accuracy is required, use the metric dimensions. Note: These units are non-load bearing. City Series CC40EPV |...
  • Page 8: Important Message

    owner's information Important Message WE RECOMMEND REMOVING THE CHILDREN AND ADULTS SHOULD BE SAVE THESE INSTRUCTIONS GLASS WITH THE GLASS VACUUM ALERTED TO THE HAZARDS OF HIGH HOLDERS SUPPLIED BY THE MANU- SURFACE TEMPERATURES, ESPE- City Series Direct Vent Fireplaces must be FACTURER.
  • Page 9: General Safety Information

    owner's information General Safety Information 1. The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes. 2. See general construction and assembly instructions. The appliance and vent should be enclosed. 3. This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.
  • Page 10: Lighting Procedure

    owner's information Lighting Procedure IMPORTANT: The remote control system supplied with this appliance has Note: The first try for ignition will last approximately 60 seconds. If there is no several options for starting/operating the appliance using the battery holder flame ignition (rectification) the board will stop sparking for approximately and ON/OFF key on the hand held transmitter. 35 seconds. After wait time , the board will start second try for ignition by Prior to operating this appliance, please read the remote control operating sparking for approximately 60 seconds . If there is still no positive ignition instructions (packaged with remote control) to understand how to operate the board will go into lock out. this remote control system. The system will need to be reset as follows: 1. Ensure the battery holder switch is in the Remote position and / or wall mounted battery holder (if equipped) is in the <REMOTE> position. a) Turn the system off by pressing the ON/OFF button on the remote. 2. Press and release the ON/OFF button on the remote handheld transmitter b) Wait 5 minutes then repeat from step 2. (see Diagram 1). An audible beep should be heard from the receiver. If not using the remote, the unit can also be turned on by sliding the battery Shutdown Procedure holder switch to the <ON> position (if equipped). 1. Press the ON/OFF button on the remote 2. If service is to be performed, you must disconnect power and shut off gas to the unit. ON/OFF Button Diagram 1...
  • Page 11: Copy Of The Lighting Plate Instructions

    owner's information Copy of the Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1.
  • Page 12: Proflame Ii Remote Control Operating Instructions

    owner's information PROFLAME II REMOTE CONTROL OPERATING INSTRUCTIONS Proflame II Remote Control Operating Instructions IMPORTANT:The Proflame Transmitter 2 is an integrated part of the TECHNICAL DATA Proflame 2 System, which consists of these elements: • Proflame 2 Transmitter, to be used in conjunction with: REMOTE CONTROL •...
  • Page 13 owner's information Temperature indication Display Remote-Flame Control With the system in the "OFF" position, press the Thermostat Key and The profl ame has six (6) fl ame levels. With the system on, and the fl ame the Mode Key at the same time. Look at the LCD screen on the transmit- level at the maximum in the appliance, pressing the Down Arrow Key ter to verify that a C or F is visible to the right of the room temperature once will reduce the fl...
  • Page 14 owner's information Smart Thermostat (Transmitter Operation) Remote dimmer control (Light)** The auxiliary function controls the AUX power outlet by the dimmable The Smart Thermostat function adjusts the fl ame height in accordance light control. To activate this function use the Mode Key (fi g. 1) to index to the difference to the AUX icon (fi...
  • Page 15 owner's information Continuous Pilot/Intermittent Pilot (CPI/IPI) selection 5. "Clr" will remove the mode by using the up or down arrow while still holding both buttons (icon will disappear once removed, or icon will show up again once added). Note: Power vent models do not have a Continuous 6.
  • Page 16: Inner Glass Panel (Firebox Glass) Installation / Removal

    owner's information Inner Glass Panel (Firebox Glass) Installation / Removal To watch the firebox installation video click here http://bit.ly/2qfQwST Note: glass panels must be installed to operate fireplace Push side glass WARNING: GLASS HANDLING panel firmly to back wall We recommend using the glass vacuum holders supplied by the manufac- until springs are turer. Lower the glass to rest in a safe place, this is to prevent damage to the compressed— glass edges. Extra care must be taken when removing/installing the glass. then close Breakage or damage to the edge of the glass which occurs as a result of clamps. careless handling will not be covered under warranty. • W e recommend handling the glass with supplied vacuum clamps •...
  • Page 17 owner's information 5. E nsure all 7 front clamps are in the open position to allow clearance for Note: Ensure that the front glass is centered and evenly spaced with side glass tooltip the glass. (3 sided unit) - open to release glass clamps to remove from surface of glass. Open clamps prior to placing front glass panel Open clamps to CC40LE shown release pressure on the springs 6. L ift up the front panel using the supplied vacuum clamps and position into the lower front channel–ensure the front panel is accurately centered—with the front panel in position—secure in place by closing the 3 lower clamps 7. Return to the side panel(s), and release the upper and lower clamps. The and 4 upper clamps. springs will release and push the glass side panel forward slightly—this will create a seal between the front and side panels. When the junction between Press glass vacuum clamps in open position firmly onto surface of glass. Bring the front and side glass panels is sealed, close the clamps to secure the handles together to close.
  • Page 18: Outer Safety Glass Panel (Barrier Glass) Installation / Removal

    owner's information Outer Safety Glass Panel (Barrier Glass) Installation / Removal To watch the safety barrier glass installation video click here http://bit.ly/2ryq0c0 Note: safety glass panels must be installed to operate fireplace 3. T ilt the top of the glass panel inward and lift up and underneath the upper front panel of the outside frame. Hook the glass panel WARNING: GLASS HANDLING onto the pins and also onto the two angle adjustment brackets lo- cated on the frame in two locations as shown in the diagram below.
  • Page 19: Outer Safety Glass Panel (Barrier Glass) Installation / Removal

    owner's information Outer Safety Glass Panel (Barrier Glass) Installation / Removal Note: safety glass panels must be installed to operate fireplace. Note: A fter the side panel has been adjusted so it is installed at 90º to the 4. F or 3 sided and corner units only: unit and not flaring in or out, check to ensure there is no gap between With front panel installed, proceed to install the side panel(s). the front and side panel. If there is a gap as shown below, slide the side I dentify the left and right side panels before installing. Facing the front of panel to adjust the position and close the gap. the unit, the right panel will show an arrow pointing to the front of the unit as shown in the diagram below. Direction arrow on side panel bracket, should point toward front of unit 5. Lift up the side panel with the supplied glass clamps (see procedure on...
  • Page 20: Maintenance Instructions

    If the glass gasket requires replacement use a the flow of combustion and ventilation air is not tadpole glass gasket (Part # 936-220). obstructed. Note: Never operate the appliance without Glass the glass properly secured in place. Your Regency fireplace is supplied with high ® 6. Do not use this appliance if any part has been temperature 5mm-Tempered outer glass & 5mm- under water. Immediately call a qualified service Ceramic inner glass. If your glass requires cleaning, technician to inspect the appliance and to...
  • Page 21 requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 22: Locating Your Gas Fireplace

    installer's information Locating Your Unit Assembly Prior to Installation Gas Fireplace Before you Start 1. When selecting a location for your fireplace, The CC40LE/CC40RE has 4 standoffs, 2 on one side and 2 at the back that need assembly before ensure that the clearances are met. installation. 2. The appliance must be installed on a flat, solid, continuous surface For example a wood, metal Side and Back Standoff Assembly CC40LE/CC40RE or concrete floor or in a raised (on the wall) ap- The standoffs are shipped in a flat position and must be folded into shape and attached. plication. The appliance must be installed on a metal or wood panel extending the full width Take each standoff off the unit by removing one screw and bend into the correct shape. Slot the 2 tabs and depth of the appliance. of the stand off into the slots in the unit and attach the other end with one screw.
  • Page 23: Installation Checklist

    requirements installer's information Installation Checklist This includes: 1. Locate appliance. Refer to the following sections: a) Locating Your Fireplace 1. Clocking the appliance to ensure the correct b) Clearances firing rate (rate noted on label 28,500 Btu/h NG/ c) Combustible Mantel Clearances LP) after burning appliance for 15 minutes. d) Framing & Finishing e) Venting. See the "Venting Introduction" to 2. If required, adjusting the primary air to ensure "Venting Arrangements"...
  • Page 24 tooltip installation Nailing Strips CC40LE/CC40RE Nailing strips are shipped folded flat against the unit. Fold nailing strips out 90º before installing unit. Secure nailing strips to framing using wood or metal screws. Side nailing strip CC40RE tooltip Side nailing strip CC40LE Top nailing strip Top Nailing Strip CC40LE/CC40RE Nailing strip is shipped with the appliance and will need to be attached. Note that the nailing strips are not required if using the optional chase or extended framing kit and may be recycled. Top nailing strip 1. S ecure nailing strip to appliance with 2 screws. 2. S ecure nailing strips to framing using wood or metal screws.
  • Page 25: Clearances Cc40Le/Cc40Re

    installation Clearances CC40LE/CC40RE The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Note: CC40LE shown in illustration. Clearances will be the same for the CC40RE. Flue Clearances to Combustibles Clearance: single sided Dimension Measured From: Horizontal - Top 3" A: Mantel Height (min.) Top of Fireplace Opening Horizontal - Side 2" B: Opening Height 15-1/16" (382mm) Bottom/Top of Fireplace Opening Horizontal - Bottom 2"...
  • Page 26: Clearances Cc40Le/Cc40Re

    installation Clearances CC40LE/CC40RE Lo w framing with vents Low framing with vents in front/sides or top CC40LE shown Floor to ceiling with top op Floor to ceiling with top opening CC40LE shown | City Series CC40EPV...
  • Page 27: Clearances Cc40Le/Cc40Re

    installation Clearances CC40LE/CC40RE Chase enclosed CC40LE shown Full framing with low vents in front or sides CC40LE shown Full framing with vents in front or sides City Series CC40EPV |...
  • Page 28: Mantel Clearances Cc40Le/Cc40Re

    installation Mantel Clearances CC40LE/CC40RE Combustible mantel clearances from top of front facing are shown in the diagram on the right. 1/2" Drywall, wood, wood panel, etc. 12" (305mm) 9" 5-1/8" Top of Bottomof Fireplace Fireplace Opening Opening 15-1/16” | City Series CC40EPV...
  • Page 29: Framing Dimensions Cc40Le (Left Corner)

    installation Framing Dimensions CC40LE (Left Corner) NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs. Note: A combined minimum of Framing 120 square inches of open area Description CC40LE Dimensions is required for the convection air outlet to cool the enclosure. En- Framing Height 37-3/8” (949mm) sure clearances for Convection Air Framing Width 48-1/4" (1226mm) Outlets are met.
  • Page 30: Framing Dimensions Cc40Re (Right Corner)

    installation Framing Dimensions CC40RE (Right corner) NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs. Framing Description CC40RE Dimensions Framing Height 37-3/8” (949mm) Framing Width 48-1/4" (1226mm) Framing Depth 19" (483mm) Note: A combined minimum of 120 square inches of open area Unit Base to Top Enclosure (Min.) 63"(1600mm) is required for the convection air Vent Centerline Height 56-1/4" (1429mm) outlet to cool the enclosure. En- sure clearances for Convection Air Outlets are met.
  • Page 31: Wall Board/Drywall Installation Cc40Le/Cc40Re

    installation Wall Board/Drywall Installation CC40LE/CC40RE WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in. thick are specified in this installation manual to properly align with the optional finishing methods offered with this appliance. The CC40LE/CC40RE may be finished to the appliance opening with 1/2 inch thick drywall. • Ensure that the back and side clearances are maintained. WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Inadequate air space could cause overheating and fire. DO NOT use screws more than 3/4 inch in length on the lower access cover panel. Longer screws may penetrate gas line or damage valve or electrical components. Note: It is acceptable to use a high temperature silicone sealant to adhere drywall to lower access cover panel. The appliance is designed to be used with 1/2 in. wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials. Thicker materials may be used. Refer to facing and finishing details in this manual. Facing Material • Facing and/or finishing materials must never overhang into the glass opening. • Facing materials may be combustible or non-combustible WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation. PAINTING If desired finishing includes a painted wall, 100% acrylic latex, oil-based or standard acrylic paints may be used. Follow paint manufacturer’s instructions for paint and primer application. 16 " [30mm] 8 " [22mm] CC40LE - screws in shaded area only 3" [76mm] 1.188 [30mm] CC40RE - screws in shaded area only 8 "...
  • Page 32: Framing And Finishing Inset Installations Cc40Le/Cc40Re

    installation Framing and Finishing Inset Installations CC40LE/CC40RE 1. Frame in the enclosure for the unit with framing material Note: When constructing the framed opening ensure there is sufficient access to install the gas lines,electrical. Also the wiring harness must be wall mounted using the receptacle provided with the appliance. The wiring harness will be located on the right hand side of the appliance if facing the unit from the front. This must be done prior to any finishing. 2. F or exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues. 3. T o ensure the chase is sealed from the outside wall into the room, all joints on the facing wall MUST be sealed, mudded, and taped to finish.
  • Page 33: Optional Framing Kit Installation Cc40Le/Cc40Re

    CITY SERIES installation Optional Framing Kit Installation CC40LE/CC40RE CC40LE/CC40RE FRAMING KIT INSTALLATION To watch the framing kit installation video click here http://bit.ly/2qvHIsE This framing kit is for the CC40LE/CC40RE. The parts are adaptable so 1. This framing kit requires the installation of two studs at locations shown the same kit can be installed on either the right or left side units.
  • Page 34 CITY SERIES installation 3. Install B to the side of the unit, use the holes corresponding with the 5. Slide unit against wall and line up part C's with studs in the wall. appropriate shape (diamond or square depending on which unit you Attach both part C's to studs with at least two screws each;...
  • Page 35 CITY SERIES installation 12. Identify J (diagonal support) and attach to back corners C and front 9. Identify F and attach to both E and D with 2 screws on each side. corner F with 2 screws on each side.
  • Page 36: Building Additional Framing Off Of The Framing Kit

    CITY SERIES Building Additional Framing Off of the Framing Kit BUILDING FRAMING OFF OF THE KIT Potential Wood Framing installs This framing kit is designed as a base in which to build additional framing. Studs can be affi xed to all outer faces using the holes identifi...
  • Page 37: Tv Recessed Into Wall - Typical Installs

    installation TV Recessed into Wall - Typical Installs CB40 Typical Installs CB40 Typical Installs Maximum TV Recess TV Flush with Hearth MAXIMUM TV RECESS FLUSH TV WITH HEARTH MAXIMUM TV RECESS FLUSH TV WITH HEARTH Max 3” Max 3” Max 3” Max 3”...
  • Page 38: Wall Mount On / Off Switch Installation

    installation Wall Mount On / Off Switch and Battery Holder Installation Required for all installations IMPORTANT INSTALLATION NOTE: The Battery Holder must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE SWITCH MUST BE ACCESSIBLE Battery Holder Installation 1. Install the low voltage junction box to the framing, at desired location within 10-1/2 ft. from fireplace. 2. F eed the 6 pin connector wiring harness through the opening at back of junction box. The wiring harness is located near the gas valve and will need to be routed to the exterior of the fireplace from either the left or right hand side prior to finishing.
  • Page 39: Exterior Vent Termination Locations

    installation Exterior Vent Termination Locations Fixed Closed Fixed Closed Openable Openable Air Supply Outlet Area where terminal is not permitted Vent Termination Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 29"(74cm) 29"(74cm) from the center line of the terminal (check with the local code) Clearance to unventilated soffit 20"(51cm) 20"(51cm) Clearance to outside corner: with PowerVent Termination Cap.
  • Page 40: Venting Arrangements For Horizontal Terminations

    installation Venting Arrangements for Horizontal Terminations RIGID PIPE: MUST USE RIGID PIPE ADAPTOR 770-994 AND 946-606 PIPE REDUCER TO 4" X 6 5/8" Note: Rigid pipe is approved for up to 72 feet. Note: Flex pipe is approved for up to 40 feet using 2 X 946-756-- 20 foot flex kits. The gas power vent system is designed to allow the installation of a gas appliance when typical vent configurations (shown in this manual) are not possible. Horizontal (Feet) 72' overall length Ma (shown with 5 - 90º elb 72' overall length Max. (shown with 5 - 90º elbows) Restrictor – Fully O Restrictor – Factory Set @ 1" 72' overall length Max.
  • Page 41: 4"X 6-5/8" Rigid Pipe Cross Reference Chart

    ” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
  • Page 42 installation Description Selkirk American Metal Security ICC Excel Olympia Simpson Metal-Fab™ Ventis DV* Direct Temp™ Products® Secure- Vent® Direct Direct Vent Pro ® Sure Seal Amerivent Direct Attic Insulation Shield 12” 46DVA-IS 4DAIS12 SV4RSA VDV-AIS04 N/A@ FPI Attic Insulation Shield 4DAIS12 TM-4AS - Cold Climates 36”...
  • Page 43: Horizontal Terminations - Rigid Pipe 4" X 6-5/8

    installation Horizontal Terminations Rigid Pipe 4" x 6-5/8" The minimum components required for a basic horizontal termination are: 1 Power Vent Kit 1 Rigid Pipe Adaptor 1 Length of pipe to suit wall thickness and total vent run (see Table 1) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. Create a level surface to mount the vent terminal. The T erminal must not be recessed into siding. Measure the wall thickness. Flat Wall Installation Powervent Kit (Part #946-535) Wall Thickness Vent Length Required (inches) (inches) 4" - 5-1/2" 6" 7" - 8-1/2" 9" 10" - 11-1/2" 12" Adj.Pipe Length 9" - 14-1/2' 11" - 14-5/8" Adj. Pipe 90 Elbow 15" - 23-1/2"...
  • Page 44: Gas Power Vent Installation Cc40Epv - Rigid Vent

    Models Equipped with Surefi re Ignition The Power Vent system can only be used with units that have been tested with the Regency Power Vent system. Downward vertical vent runs are permitted with the Surefi re Ignition system. See vent confi guration in unit manual.
  • Page 45: Gas Power Vent Installation Cc40Epv - Flex Vent

    Models Equipped with Surefi re Ignition The Power Vent system can only be used with units that have been tested with the Regency Power Vent system. Downward vertical vent runs are permitted with the Surefi re Ignition system. See vent confi guration in unit manual.
  • Page 46: Unit Installation With Horizontal Termination - 4" X 6-5/8" Venting

    installation Unit Installation with Horizontal 5. Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock Termination for a solid connection. 4" X 6-5/8" VENTING (Rigid Vent Systems) Note: For best results and optimum performance with each approved Minimum Vent Clearances v e n t i n g s y s t e m , i t i s h i g h l y to Combustibles recommended to apply Mill-Pac sealant (supplied) to every inner...
  • Page 47: Vertical Flue Extension Kit (Part #946-756)

    installation Vertical Flue Extension Kit (Part #946-756) VERTICAL FLUE EXTENSION KIT (APPROVED MODELS) HORIZONTAL POWER VENT KIT (CV72EPV, CB72EPV, CB40EPV, CV40EPV, & CC40EPV ONLY) (PART # 946-756) 20 foot Flex pipe Extension 4" (100mm) inner pipe Used in conjunction with the 946-755 Vertical Flex kit for vertical installations 20ft.
  • Page 48: Power Vent Terminal Installation

    installation CV40EPV / CB40EPV / CC40EPV Power vent terminal installation Power Vent Terminal Installation 6. Determine the building fi nishing material thickness. WARNING 7. Depending on the building material thickness, install the frame onto ELECTRICAL CONNECTIONS SHOULD ONLY BE the Power Vent mount using 4 screws. Mounting holes start at 2" CARRIED OUT BY A QUALIFIED AND LICENSED from the front of the Power Vent unit cover and can be adjusted back ELECTRICIAN...
  • Page 49 CV40EPV / CB40EPV / CC40EPV installation 14. Install the second grommet onto the wires and secure grommet and 10. Remove front faceplate from Power Vent unit by removing 4 screws wires into a bracket located on the side of the Power Vent box as shown below.
  • Page 50: Gas Power Vent Installation - Wiring The Power Vent To The Unit

    installation CV40EPV / CB40EPV / CC40EPV Gas Power Vent Installation - Wiring the Power Vent to the Unit Gas Power Vent Installation--wiring the power vent to the unit 3. Bring the BX cable through the strain relief as shown below. An overall Access panel removal length of approx.
  • Page 51 CV40EPV / CB40EPV / CC40EPV installation 6. Secure wires from both the BX cable and IFC wiring harness using 9. Tuck the 4 completed wires neatly next to the IFC board as shown below. sup-plied wire marrettes. -blue to blue -red to red -black to black -white to white...
  • Page 52 CV40EPV / CB40EPV / CC40EPV installation 12. Reinstall IFC cover removed in Step 7. 13. Once wiring is complete, plug unit into power located on the left side of the unit to junction box. Junction Box 14. Reinstall access panel removed in Step 1. 10.11.18 919-920 | City Series CC40EPV...
  • Page 53: High Elevation

    CC40LE/CC40RE Pilot Ignitor LP SYSTEM DATA Min. Supply Pressure 11" WC (2.73 kpa) Note: If you have an incorrect flame Manifold Pressure 10.5" WC (2.62 kpa) pattern, contact your Regency ® Orifice Size #53 DMS dealer for further instructions. Maximum Input 28,500 Btu/h Incorrect flame pattern will have small, probably (8.35 kW) yellow flames, not coming into proper contact...
  • Page 54: Wiring Diagram

    installation Wiring Diagram No electrical power supply is required for the gas (Do not cut the ground terminal off under any Caution: Ensure that the wires do not circumstances.) control to operate. 120 Volt AC power is needed touch any hot surfaces and are away from for the lights. A receptacle box, receptacle and sharp edges. cover are provided and located on the left hand side of the unit, under the outer base panel.
  • Page 55: Inner Glass Panel (Firebox Glass) Installation / Removal

    installation Inner Glass Panel (Firebox Glass) Installation / Removal To watch the firebox installation video click here http://bit.ly/2qfQwST Note: glass panels must be installed to operate fireplace Push side glass WARNING: GLASS HANDLING panel firmly to back wall We recommend using the glass vacuum holders supplied by the manufac- until springs are turer. Lower the glass to rest in a safe place, this is to prevent damage to the compressed— glass edges. Extra care must be taken when removing/installing the glass. then close Breakage or damage to the edge of the glass which occurs as a result of clamps. careless handling will not be covered under warranty. • W e recommend handling the glass with supplied vacuum clamps •...
  • Page 56 installation 5. E nsure all 7 front clamps are in the open position to allow clearance for Note: Ensure that the front glass is centered and evenly spaced with side glass tooltip the glass. (3 sided unit) - open to release glass clamps to remove from surface of glass. Open clamps prior to placing front glass panel Open clamps to CC40LE shown release pressure on the springs 6. L ift up the front panel using the supplied vacuum clamps and position into the lower front channel–ensure the front panel is accurately centered—with the front panel in position—secure in place by closing the 3 lower clamps 7. Return to the side panel(s), and release the upper and lower clamps. The and 4 upper clamps. springs will release and push the glass side panel forward slightly—this will create a seal between the front and side panels. When the junction between Press glass vacuum clamps in open position firmly onto surface of glass. Bring the front and side glass panels is sealed, close the clamps to secure the handles together to close. side panel(s) in place.
  • Page 57: Outer Safety Glass Panel (Barrier Glass) Installation / Removal

    installation Outer Safety Glass Panel (Barrier Glass) Installation / Removal To watch the safety barrier glass installation video click here http://bit.ly/2ryq0c0 Note: safety glass panels must be installed to operate fireplace 3. T ilt the top of the glass panel inward and lift up and underneath the upper front panel of the outside frame. Hook the glass panel WARNING: GLASS HANDLING onto the pins and also onto the two angle adjustment brackets lo- cated on the frame in two locations as shown in the diagram below.
  • Page 58: Outer Safety Glass Panel (Barrier Glass) Installation / Removal

    installation Outer Safety Glass Panel (Barrier Glass) Installation / Removal Note: safety glass panels must be installed to operate fireplace. Note: A fter the side panel has been adjusted so it is installed at 90º to the 4. F or 3 sided and corner units only: unit and not flaring in or out, check to ensure there is no gap between With front panel installed, proceed to install the side panel(s). the front and side panel. If there is a gap as shown below, slide the side I dentify the left and right side panels before installing. Facing the front of panel to adjust the position and close the gap. the unit, the right panel will show an arrow pointing to the front of the unit as shown in the diagram below. Direction arrow on side panel bracket, should point toward front of unit 5. Lift up the side panel with the supplied glass clamps (see procedure on previous page). Tilt the side of the glass panel inward and lift up and under-...
  • Page 59: Lp Conversion Instructions

    CITY SERIES installation CONVERSION FROM NG TO LP LP Conversion Instructions CV40E/ CB40E/CC40E-11 using SIT 885 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION! WARNING 6. If unable to access this Cable - undo 2 screws securing the IFC Board This conversion kit shall be installed by a qualified and slide out of unit to access cable.
  • Page 60 CITY SERIES installation 11. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner to the left away from the orifice and lift out. front screw locations 14. Unscrew the pilot orifice with the allen key; then replace with the LPG pilot orifice and the pilot cap, provided in the kit.
  • Page 61: Cc40Le/Cc40Re Painted Panel Installation

    Note: Install inner safety glass prior to installation of outer panels-see instructions in manual 1. Attach Regency logo to the right hand side of outer front panel. The magnets will be positioned under the outer front base panel to secure 2.
  • Page 62: Cc40Le/Cc40Re Glass Panel Installation

    CITY SERIES CC40LE/CC40RE Glass Panel Installation CC40LE/CC40RE GLASS PANEL INSTALLATION 1. Turn off unit and allow to cool to room temperature. Remove the outer safety 4. Slide the supplied bottom corner bracket behind the small panel (1) and the glass and inner ceramic fi...
  • Page 63 CITY SERIES installation 6. Carefully manoeuver the Side Glass Panel (3) into the side of the fi re- 9. Install outer side base panel (5) — panel 5 rests on the tab of panel 4. box. Position the bottom of the panel into the Bottom Corner Bracket and secure the top using the Top Side Bracket as shown.
  • Page 64: Cc40Le/Cc40Re Enamel Panel Installation

    maintenance CITY LINE CC40LE/CC40RE Enamel Panel Installation CC40RE/CC40LE ENAMEL PANEL INSTALLATION Black Enamel Panels — Handling Instructions • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. •...
  • Page 65 Note: Install inner safety glass prior to installation of outer panels-see instructions in manual 1. Attach Regency logo to the right hand side of outer front panel. The magnets will be positioned under the outer front base panel to secure the logo.
  • Page 66: Burner And Firebox Media Options

    installation Burner and Firebox Media Options Spread the media evenly over the burner. Ensure the glass/stones do not overlap excessively as this will affect the flame pattern. IMPORTANT NOTE: Only the supplied approved media are to be used with these fireplaces. Use of any other type of glass or stones can alter the unit's performance. Any damage caused by the use of any unapproved glass or stones will not be covered under warranty. When using Ceramic Spa/Volcanic Stones ensure required glass crystals/beads are used as a base. DO NOT overstack Ceramic Spa Stones or Volcanic Stones on burner or in the pilot area. Media must be installed on and around burner only in amounts noted below. CC40LE/CC40RE Approved Media* Where Used Quantity Fireglass (starfire, copper or black) On burner 1.5 lbs Glowing embers/sea wool (supplied with unit) On burner 1 bag Natural Stones Around burner 1 box = 15lbs Ivory Natural Stones Around burner 1 box = 15lbs 3/4" Crushed black glass Around burner 3.5lbs Crushed Iceburg chips Around burner 3.5lbs Firebeads Around burner 3.5lbs Spa stones Around burner...
  • Page 67: Optional Driftwood Log Set Installation

    installation CITY LINE Optional Driftwood Log Set Installation CITY LINE - LOG INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
  • Page 68 CITY LINE installation 8. Place the split end of Log 3 to the right front corner of the burner—angle Rest the other end of Log 4 on the indent in Log 2 as shown below. the log so that the other end is sitting approximately 1/2" (13mm) from the edge of the burner tray.
  • Page 69: Optional Birchwood Log Set Installation

    CITY LINE installation Optional Birchwood Log Set Installation OPTIONAL BIRCHWOOD LOG SET INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
  • Page 70 CITY LINE installation 7. Position Log 2 as shown and follow the measurements. 11. Place Log 4—identify the pin locator and match with the left side pin on Log 1. Rest the Log 4 on the indent in Log 2 as shown below. Log 2 in position 8.
  • Page 71: Cc40Le/Cc40Re - Removable Drywall Guides

    installation CC40LE/CC40RE - Removable Drywall Guides (when using 1/2" drywall) An optional finishing trim is available to finish the edges of the installation on 5. R everse steps to reinstall drywall guides (if applicable). If discarding, please the CC40RE/CC40LE unit. Installation is as follows: recycle. 1. R emove the outer safety glass and outer front and side panels - see in- structions in manual. 2. L oosen 3 screws inside the lower front edge of the unit to release existing lower drywall guide and remove guide. Note : an offset screwdriver is provided with the appliance for ease of removal/ installation of the lip and finishing trim. Lower drywall guides Loosen and tighten screws on drywall guide from inside front panel 3. L oosen 2 screws from inside the firebox to release the existing side drywall guide, remove guide and recycle.
  • Page 72: First Fire

    operating instructions First Fire Normal Operating Sounds of Gas Aeration Adjustment Appliances The burner aeration is factory set but may need The FIRST FIRE in your fireplace is part of the paint adjusting due to either the local gas supply or curing process. T o ensure the paint is properly cured, It is possible that you will hear some sounds from altitude. Open the air shutter for a blue flame or it is recommended you burn your fireplace for at your gas appliance. This is perfectly normal due to close for a more yellow flame.
  • Page 73: Bulb Replacement

    Bulb Replacement 1. T urn off unit and allow to cool to room temperature. 4. Loosen 2 screws on each side of individual inner light cover and remove. 2. R emove outer safety glass panels and inner panels (firebox glass)–see 5. R emove glass cover by using a flat head screwdriver to pry the tab securing instructions in this manual. the glass assembly in place. 3. L oosen 2 outer screws on each side to remove outer light cover — located 6. Replace bulb and reverse steps to complete procedure. in the upper inside front of the firebox and remove. NOTE: D o not handle bulb with bare hands. Use packaging or a tissue to hold new bulb when replacing. Regency Part# 911-208 Oven Lamp Assembly G9 120V/25W Regency Part# 911-072 Replacement Bulb G9 120 Volt/25 watt City Series CC40EPV |...
  • Page 74: Valve Replacement

    maintenance Valve Replacement Important: Always shut off gas supply/120 volt power prior to servicing the 7. L ift valve tray by out partially and disconnect flexible gas connection on the gas valve. valve inlet side, remove valve tray- replace with new valve tray. tooltip 1. T urn off unit and allow to cool to room temperature. 2. R emove outer enamel or steel panels—see instructions in the panel removal section in this manual 3. R emove outer safety glass panels and inner panels (firebox glass)–see instructions in this manual. 4. Remove all media and logs (if installed) — set aside. 5. L oosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner to the left away from the orifice and lift out. Front screw locations 8. Reverse steps 6-1 to complete. Back screw locations 6. Remove 16 screws in locations shown below.
  • Page 75: Cc40Le Main Assembly

    Receptacle Cover Duplex Metal 940-436/P Flush Inner Ceramic Glass - Large 904-687 Connector Clamp 3/8 CI-804 656-062 Outer Base Cover Black 948-078 Glass Suction Cup (Each) 940-440/P Outer Safety Glass Side - Tempered Small 904-790 Magnet Round 1/2 inch (Each) 940-437/P Flush Inner Ceramic Glass Small 904-970 Magnet Cup 1/2 inch (Each) 656-574/P Valve Assembly - NG 948-223 Logo Plate Plastic Regency/Flame Silver 656-776/P Valve Assembly - LP 656-131 Logo Mounting Bracket 656-017F Restrictor Plate 656-033F Bottom Cover Access Plate 656-034 Bottom Cover Access Gasket 656-018 Pressure Relief Base 656-309 Removable Drywall Finishing 656-023 Pressure Relief Base Gasket 656-019 Pressure Relief Bracket Right 656-124...
  • Page 76 parts list 656-059 Inner Top Panel Clip (Used on the 656-928) 946-776 Fireglass Copper 1/4 in. 5Lb Pkg 656-930/P Driftwood Log Set 946-777 Fireglass Starfire 1/4 in. 5Lb Pkg 657-977 Conversion Kit - LP 946-780 Crushed Glass Coal Black 3/4in. 3.5 Lbs 656-991 Chase Vent Front Black 946-781 Crushed Glass Iceberg Chips 3/4in. 3.5 Lbs 656-995 Adaptor Heat Wave 946-735 Firebeads Black 1 Lb Pkg 946-556 Heatwave Kit 946-736 Firebeads Sangria Luster 1 Lb Pkg 946-672 Stones - River Pebbles 946-737 Firebeads Glacier Ice 1 Lb Pkg 946-674 Stones - Ceramic Spa (70 stones) 946-738 Firebeads Caramel Luster 1 Lb Pkg 946-675 Fireglass Black Reflective 1/4in.1Lb Pkg 946-739 Firebeads Black 5 Lb Pkg 946-676 Fireglass Copper 1/4 in. 1Lb Pkg 946-740 Firebeads Sangria Luster 5 Lb Pkg 946-677...
  • Page 77: Cc40Re Main Assembly

    Receptacle Cover Duplex Metal 940-436/P Flush Inner Ceramic Glass - Large 904-687 Connector Clamp 3/8 CI-804 656-062 Outer Base Cover Black 948-078 Glass Suction Cup (Each) 940-439/P Outer Safety Glass Side - Tempered Small 904-790 Magnet Round 1/2 inch (Each) 940-437/P Flush Inner Ceramic Glass Small 904-970 Magnet Cup 1/2 inch (Each) 936-219 Gasket 5/8 (09) Sewn Rope Graphite 3/4 PSA 10 948-223 Logo Plate Plastic Regency/Flame Silver (Sold per Foot 10 Feet Required) 656-131 Logo Mounting Bracket 936-220 Gasket Tape 2" Wide Graphite Wrap 656-017F Restrictor Plate 656-018 Pressure Relief Base 656-574/P Valve Assembly - NG 656-023 Pressure Relief Base Gasket 656-576/P Valve Assembly - LP 656-019 Pressure Relief Bracket Right 656-033F Bottom Cover Access Plate...
  • Page 78 parts list 656-969 Conversion Kit - LP 946-780 Crushed Glass Coal Black 3/4in. 3.5 Lbs 656-991 Chase Vent Front Black 946-781 Crushed Glass Iceberg Chips 3/4in. 3.5 Lbs 656-995 Adaptor Heat Wave 946-735 Firebeads Black 1 Lb Pkg 946-556 Heatwave Kit 946-736 Firebeads Sangria Luster 1 Lb Pkg 946-672 Stones - River Pebbles 946-737 Firebeads Glacier Ice 1 Lb Pkg 946-674 Stones - Ceramic Spa (70 stones) 946-738 Firebeads Caramel Luster 1 Lb Pkg 946-675 Fireglass Black Reflective 1/4in.1Lb Pkg 946-739 Firebeads Black 5 Lb Pkg 946-676 Fireglass Copper 1/4 in. 1Lb Pkg 946-740 Firebeads Sangria Luster 5 Lb Pkg 946-677 Fireglass Starfire 1/4 in. 1Lb Pkg 946-741 Firebeads Glacier Ice 5 Lb Pkg 946-775 Fireglass Black Reflective 1/4in.5Lb Pkg 946-742 Firebeads Caramel Luster 5 Lb Pkg 946-776...
  • Page 79: Power Vent

    parts list Power Vent Part Number Description 911-112/P Pressure Switch/Sensor (includes Bracket) 911-244/P Power Vent Fan Assembly 905-017 Straight Wire Connector/Clamp 946-536 Power Vent SS Front Faceplate 946-130 Power Vent SS Outer Perimeter Trim 946-157 Power Vent SS Water Deflector 911-047 Silicone Tubing (Sold Per Foot) (6 inches required For Power Vent) 946-163 Pressure Switch/Sensor Bracket 946-539 Power Vent Outer Intake Assembly 946-540 Power Vent Inner Intake Assembly 911-254 Pressure Switch Wire Harness Blue/Red 911-255 Pressure Switch Wire Harness Shrink Wrapped Blue/Red City Series CC40EPV |...
  • Page 80: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty | City Series CC40EPV...
  • Page 81 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty City Series CC40EPV |...
  • Page 82 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 83 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 84 | City Series CC40EPV...
  • Page 85 notes City Series CC40EPV |...
  • Page 86 notes | City Series CC40EPV...
  • Page 88 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ © Copyright 2019, FPI Fireplace Products International Ltd. All rights reserved.