Regency City CP60E Owners & Installation Manual page 47

Table of Contents

Advertisement

CITY SERIES 60
12. Loosen 8 screws in the locations shown below (4 at front and 4 at
rear)—slide the burner to the left, away from the orifice, and lift it out.
13. Remove burner orifice with a 3/8" wrench. Use another wrench to hold
3RD ANGLE
TOLERANCES UNLESS
PROJECTION
OTHERWISE STATED
DIMENSIONS
the elbow behind the orifice. Discard the orifice. Reinstall the new burner
0.000 = 0.01 CRITICAL
0.000 = SPECIFIED TOLERANCE
DO NOT SCALE
0.000 = 0.031
DRAWING
orifice LPG stamped #50 and tighten.
0.000 REF = REFERENCE ONLY
UNITS IN INCHES
ANGULAR = 1
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT.
14. Remove the pilot retainer clip with pliers and pull off the pilot cap to
expose the pilot orifice.
3RD ANGLE
TOLERANCES UNLESS
PROJECTION
OTHERWISE STATED
DIMENSIONS
0.000 = 0.01 CRITICAL
0.000 = SPECIFIED TOLERANCE
DO NOT SCALE
Pilot retainer clip
0.000 = 0.031
DRAWING
0.000 REF = REFERENCE ONLY
UNITS IN INCHES
ANGULAR = 1
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT.
920-406a
Burner screw locations
-
FIREPLACE PRODUCTS
MAT'L :
INTERNATIONAL
SHEAR/ PUNCH/ FORM
PROCESS :
1:24
CP60 MAIN ASSEMBLY
SCALE:
PART :
11/25/2021
PART NO:
REV:
DATE:
DWN:
457-500
-
E.C.N.:
SIGN:
DATE:
Burner Orifice Location
FIREPLACE PRODUCTS
INTERNATIONAL
1:24
SCALE:
DWN:
E.C.N.:
15. Unscrew the pilot orifice with the Allen key, then replace it with the LPG
pilot orifice and the pilot cap provided in the kit.
16. Reinstall the pilot cap and pilot retainer clip.
17. Prior to installing the burner, adjust the aerations settings to 3/8" for LP.
Reinstall the burner (see step 11).
18. Make sure the aeration cap tab is inserted into the slot on the bracket.
Adjust the aeration handle if necessary.
Aeration Cap Tab
19. Reverse steps 1 to 11.
MAT'L :
20. Ensure the pilot light is in the correct orientation to the burner. Recon-
nect the gas and electrical supplies. Start the appliance (see section
PROCESS :
on lighting Instructions). Ensure that pilot and burner ignition are com-
PART :
pleted without delay. Check inlet and outlet pressures at full load. With
a soapy solution, leak test the entire system. Verify correct flame and
11/25/2021
DATE:
pilot appearance.
SIGN:
DATE:
21. See Gas Pipe Pressure Testing in manual.
LP SYSTEM DATA
Min. Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size
Maximum Input
Minimum Input
Altitude
Installer Notice:
These instructions must be left
with the appliance
2
installation - general
Slot on bracket
Aeration
handle
-
SHEAR/ PUNCH/ FORM
CP60 MAIN ASSEMBLY
PART NO:
457-500
City Series
11" WC (2.73kpa)
10.5" WC (2.62 kpa)
2.9" WC (0.72 kpa)
#50 DMS
36,000 Btu/h (10.54 kW)
19,500 Btu/h (5.71 kW)
0-4500 ft (0-1372m)
.
04.07.22
City Series CP60E |
REV:
-
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

City seriesCity cp60e-ngCity cp60e-lp

Table of Contents