CV40E-12 Direct Vent
STYLE
Single sided
Warning
Fire or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by :
Certified to/Certifié pour: CSA 2.17-2017
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
920-565
City Series
®
MODEL
CV40E-NG12 / CV40E-LP12
ANSI Z21.88-2019
CSA 2.33-2019
Installer: Please complete the details on the back cover and
leave this manual with the homeowner.
Homeowner: Please keep these instructions for future
reference.
Owners &
Installation Manual
San Francisco Bay
CB40E-NG1
Installation video
http://bit.ly/2vjpzmr
www.regency-fire.com
08.04.22

Advertisement

Table of Contents
loading

Summary of Contents for Regency CV40E-12

  • Page 1 City Series ® Owners & CV40E-12 Direct Vent Installation Manual San Francisco Bay CB40E-NG1 Installation video http://bit.ly/2vjpzmr www.regency-fire.com STYLE MODEL Single sided CV40E-NG12 / CV40E-LP12 Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 ® been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The CV40E-12 City Series has been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3 This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible fore use with other gases, unless a certified kit is used. City Series CV40E-12 |...
  • Page 4 After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace damper and any other gas-fired burning appliance to the previous conditions of use. | City Series CV40E-12...
  • Page 5: Table Of Contents

    DuraVent Vertical Termination - 4" X 6-5/8" Venting (Rigid Vent Systems) .................. 52 Vertical Termination - 4" x 6-7/8" Venting Flex Vent Kit (Part # 946-755) ............... 53 Vertical Flue Extension Kit (Part #946-756) ........54 Ceiling Firestop / Firestop Spacer (Part #946-757) ......54 City Series CV40E-12 |...
  • Page 6: Copy Of Safety Decal

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. | City Series CV40E-12...
  • Page 7: Dimensions

    ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT. City Series CV40E-12 |...
  • Page 8: Gas Installation Checklist

    This general checklist does not contain all pertinent installation details or specifics and does not supersede the guidelines in this manual. Your Regency dealer/installer should use it in conjunction with manual instructions. Please follow all local codes and jurisdictions in authority.
  • Page 9 Was accessing unit controls in a power outage explained to the customer? Are the model and serial numbers and the date of installation of the unit written in the manual and on the checklist? Were the warranty and unit registration reviewed with the customer? Comments: 05/18/21 City Series CV40E-12 |...
  • Page 10: Important Message

    THE APPLIANCE. IF THE BARRIER BECOMES DAMAGED, THE BARRIER SHALL BE REPLACED W I T H T H E M A N U F A C T U R E R ' S BARRIER FOR THIS APPLIANCE. | City Series CV40E-12...
  • Page 11: General Safety Information

    13. Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance. 14. The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids). City Series CV40E-12 |...
  • Page 12: Lighting Procedure

    5. Reset the system as follows: Power vent models do not have a continuous pilot option. a) Turn the system off by pressing the ON/OFF button on the remote . b) Wait 5 minutes, then repeat the process from step 2. | City Series CV40E-12...
  • Page 13: Copy Of The Lighting Plate Instructions

    DO NOT REMOVE THIS INSTRUCTION PLATE NE PAS ENLEVER CETTE ÉTIQUETTE D’INSTRUCTIONS 919-649b Part #: 919-649b City Series CV40E-12 | Colours: Black on Grey, except for parts indicated as being Red. Punch out .25" hole top right corner where indicated.
  • Page 14: Proflame Ii Remote Control Operating Instructions

    REMOTE CONTROL Supply voltage 4.5V (three 1.5V AAA batteries) Ambient temperature rat- 0 - 50 C (32 - 122 ings Typical operative distance 12 m (39 ft) in free air Radio frequency 315 MHZ (FCC version) | City Series CV40E-12...
  • Page 15 Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confi rms reception of the command. Figure 9 Figure 10 City Series CV40E-12 | 919-829 09.29.17...
  • Page 16 (fi g.1) to index to the fan control icon (Fig. 13). Use the Up/Down Arrow Keys (fi g.1) to turn on, off or adjust the fan speed (fi g. 14). A single “beep” will confi rm reception of the command. Figure 17 Figure 18 Figure 13 Figure 14 | City Series CV40E-12 919-829 09.29.17...
  • Page 17 3. Reinstall the 3rd battery while still holding both buttons (keep holding buttons once 3rd battery is installed, then release the mode button only. 4. The screen will show either "Clr" or "Set" with the 1st mode being your option to disable or enable. City Series CV40E-12 | 919-829 09.29.17...
  • Page 18: Proflame Ii Battery Holder Battery Replacement

    STEP 3 Keeping the battery compartment pressed in, close the left slide Close the right slide STEP 4 Reinstall wall cover plate with 2 Phillips head screws. | City Series CV40E-12...
  • Page 19: Wifi Dongle Installation (Optional)

    CITY SERIES 40 owner's information WIFI Dongle Installation (Optional) WIFI Dongle Installation Instructions 1. Remove the safety glass and firebox glass – see manual. 5. Line up the tabs on the dongle with the notches on the IFC connection and insert the cable into the connection. 2. Remove the front lower firebox glass pad to allow access to the IFC cover. 6. Apply Velcro strips to the bottom of the dongle and to the side of the IFC bracket. 3. Locate the 2 screws on the IFC cover and remove the cover to access the IFC. 7. Place the dongle onto the IFC bracket. 4. Locate the WIFI dongle connection (X0A) on the side of the IFC. 8. Reverse steps 1, 2 and 3. City Series CV40E-12 | 06.29.22 920-561...
  • Page 20: Inner Glass Panel (Firebox Glass) Installation / Removal

    4. Lift up the front panel using the supplied vacuum clamps and position into the lower front channel–ensure the front panel is accurately centered—with the front panel in position—secure in place by closing the 3 lower clamps and 4 upper clamps. | City Series CV40E-12...
  • Page 21: Outer Safety Glass Panel (Barrier Glass) Installation / Removal

    Clockwise = bring panel 2. Using the supplied vacuum clamps, lift the large front glass panel and Counter clockwise= bring position it front and centre by manoeuvering up and underneath the front panel out of the unit frame. City Series CV40E-12 |...
  • Page 22: Maintenance Instructions

    For relighting, refer to lighting instructions. Keep 4. Inspect joints, to verify that no pipe sections or Regency dealer only. Replacement glass is shipped the burner and control compartment clean by fittings have been disturbed, and consequently already installed into the door frame.
  • Page 23 (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. City Series CV40E-12 |...
  • Page 24: Installer's Information

    Have an authorized inspector, dealer, or installer review your plans before installation. Note: For vent terminations refer to "Exterior Vent Termination Locations" section. | City Series CV40E-12...
  • Page 25 Once complete ensure that the access panel is reinstalled prior to any finishing. The CV40E has 4 screws to remove access cover. See locations in diagrams to the right. 4 screws City Series CV40E-12 |...
  • Page 26: General Safety Information

    The 3 prong plug will be located near the gas valve on the appliance. 9. Final check. WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov 919-874 Part # - 919-874 | City Series CV40E-12 Description: Prop. 65 Short form label Date: May 30/18 Colour: Black font on white Size: 5"W x 0.7"H...
  • Page 27: Ventilation Openings

    Ventilation Openings Regency's patented Cool Wall system releases warmth at ceiling level. This system reduces excessive radiant heat in front of the fireplace so you can enjoy your fireplace more often. • Design your own chase vent solution to suit your home •...
  • Page 28: Chase Enclosure

    40” (1016 mm) Chase Vent Stud Stud In the example above, the ceiling does not meet the requirement as it is higher than the specified minimum. Top of chase enclosure is sealed off to meet the 0-3 (76 mm) requirement. | City Series CV40E-12...
  • Page 29: Clearances

    The metal ends of the standoff may NOT be if these clearances (air space) to combustible materials are recessed into combustible construction. not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. City Series CV40E-12 |...
  • Page 30 Full framing with ventilation opening in front or 2 sides Note: The ventilation opening may only be placed above, on both sides and in front as shown above. Ventilation grills can never be placed behind the appliance. | City Series CV40E-12...
  • Page 31: Optional Flush Front Chase Vent Installation - Part #657-991 (White)

    Edge finish must not decrease decrease opening area below 130in (3.25" x 40") or (83 mm x 1016 mm) opening area below 130in (3.25'' x 40'') or (83mm x 106mm) City Series CV40E-12 |...
  • Page 32 Drywall Frame wall with nishing material If necessary, mark where the Cut hole in nishing material chase vent is located before around inside of chase vent. fixing drywall in place Finish edges around opening | City Series CV40E-12...
  • Page 33: Optional Front Grill Installation - Part #656-991 (Black)

    Repeat steps to install the second grill to the other side of the chase. DIMENSIONS Maximum 3'' (76mm) from top of enclo- sure. 8-5/16'' (211mm) 8-5/16'' (211mm) Unit may not be exactly as shown, but the drawing dipicts the process. Secure with screws through louvers to the sides. City Series CV40E-12 |...
  • Page 34: Mantel Clearances

    12" (305 mm) 9" (229 m) 5-1/8" (130 mm) Top of Bottomof Fireplace Fireplace Opening 15-1/16” Opening (383 mm) Mantel Leg Clearances Combustible mantel leg clearances as per diagram: CV40E MANTEL LEG Allowable mantel leg projection 8-1/2" | City Series CV40E-12...
  • Page 35: Framing Dimensions

    * The framing depth/width does not take into account dry wall/wood or similar materials against the back /side wall. The framing depth will need to change based on the thickness of the material (example: B - 46 3/4" framing width +1/2" drywall = 47 3/4") (example: C - 19" framing depth +1/2" drywall = 19 1/2") City Series CV40E-12 |...
  • Page 36: Wall Board/Drywall Installation

    If desired finishing includes a painted wall, 100% acrylic latex, oil-based or standard acrylic paints may be used. Follow paint manufacturer’s instructions for paint and primer application. 3" 3" [73mm] [76mm] SCREWS ONLY IN SHADED AREA | City Series CV40E-12...
  • Page 37: Framing And Finishing Inset Installations

    4 screws secure the bottom lip — see Diagram 1. These will be hidden so the outer panels will need to be removed to access the screws. See outer panel removal in this manual. City Series CV40E-12 |...
  • Page 38: Tv Recessed Into Wall

    Flush wall TV recess using 1/2" (13 mm) drywall 5/8” (117 mm) maximum TV recess Flush wall TV recess using 1/2" (13 mm) drywall 5/8” using 1/2” (13 mm) drywall using 1/2” (13 mm) drywall CB40E shown CB40E shown | City Series CV40E-12...
  • Page 39: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally City Series CV40E-12 |...
  • Page 40: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    4" X 6-5/8" RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: Olympia Ventis DV is only approved for certain models. See list of approved models in cross-reference chart.
  • Page 41 TM-4ST14 Snorkel Termination 36” TM-4ST36 Wall Firestop 46DVA-WFS TM-4TR VDV-FS04 * Not available from Regency 946-506/P Vent Guard (Optional) for AstroCap 946-205 Vinyl Siding Shield for Riser Vent Terminal **510-994 Rigid Pipe Adaptor (Must use with all rigid piping) 946-208/P...
  • Page 42: Vent Restrictor Position

    Set 0 (Full open) Factory set Screw locations Vent restrictor location - inside top of firebox Diagram 1 Set 1 (Vent restrictor at 2”) Set 2 (Vent restrictor at 1.75”) Set 3 (Vent restrictor at 1.5”) | City Series CV40E-12...
  • Page 43: Venting Introduction

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
  • Page 44: Horizontal Termination - 4" X 6-5/8" Venting (Flex Vent Systems)

    Mill-Pac to the outer flex pipe and slip it over furstrpf.eps connection) the outer flue collar of the vent terminal at least Wall Thimble 2 pieces french (10" (254mm) 1-3/8"(35mm) and fasten with the 3 screws. Outer Diameter) Fourrures en bois | City Series CV40E-12...
  • Page 45: Horizontal Terminations - Flex Vent 4" X 6-7/8

    S.S. screws #8 x 1-1/2” drill point Notes: 1. Liner sections should be continuous without any joints or seams. 2. Only Flex pipe purchased from Regency may be ® used for Flex installations 3. Horizontal vent must be supported every 3 feet.
  • Page 46: Horizontal Terminations - Rigid Pipe 4" X 6-5/8

    Metal Products Ameri Vent Direct Vent, Security Secure Vent , ICC Excel, Selkirk Direct-Temp and Olympia Chimney. AstroCap is a proprietary trademark ® of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. | City Series CV40E-12...
  • Page 47 7' Max. elbows is required. elbows is Restrictor Set 0 - Factory Setting 6' Min. 5' Max. 11' Min. 8' Max. required. 7' Min. 6' Max. 12' Min. 9' Max. Restrictor Set 0 - Factory Setting City Series CV40E-12 |...
  • Page 48: Duravent Horizontal Terminations

    Failure to do so may result The four wood screws provided should be in drafting or performance issues not covered replaced with appropriate fasteners for stucco, under warranty. brick, concrete, or other types of sidings. | City Series CV40E-12...
  • Page 49: Venting Arrangement For Vertical Terminations - Straight Vertical Venting And/Or With A Max. Of Two (2)

    2 2 0 0 1 1 8 8 1 1 6 6 1 1 4 4 1 1 2 2 Vent Restrictor on Set 1 1 1 0 0 *Minimum length of pipe between elbows 12” (305mm) City Series CV40E-12 |...
  • Page 50: Vertical Terminations - Rigid Pipe 4" X 6-5/8

    Metal Products Ameri Vent Direct Vent, Security Secure Vent , ICC Excel, Selkirk Direct-Temp and Olympia Chimney. AstroCap is a proprietary trademark ® of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. | City Series CV40E-12...
  • Page 51: Vertical Terminations - Rigid Pipe 4" X 6-5/8

    6' Max 8' Min. Please note min. 1 foot between 6' Min. 7' Max 9' Min. elbows is 7' Min. 8' Max 10' Min. required. Lengths do not include elbow indicated Restrictor Set 0 - Factory Setting City Series CV40E-12 |...
  • Page 52: Duravent Vertical Termination - 4" X 6-5/8" Venting (Rigid Vent Systems)

    Note that for steep roof pitches, the vertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. | City Series CV40E-12...
  • Page 53: Vertical Termination - 4" X 6-7/8" Venting Flex Vent Kit (Part # 946-755)

    10. Attach the rigid pipe section to the adaptor by using Mill-Pac on the inner/ Note: Any closets or storage spaces which the vent passes through must outer pipe. Use 3 screws to secure outer pipe. be enclosed. City Series CV40E-12 | 919-695 08.10.16...
  • Page 54: Vertical Flue Extension Kit (Part #946-756)

    • The ceiling firestop/firestop spacer may be cut down to size if the Ceiling firestop shield is too high for the application. Firestop spacer to prevent debris from falling into the ceiling Diagram 1 Roof support firestop Ceiling firestop Enclosure Ceiling firestop Diagram 1a 919-696 | City Series CV40E-12 08.10.16 919-698 06.12.18...
  • Page 55: System Data

    Pilot Adjustment 885 S.I.T. Valve Description CV40E-12 NG System Data Min. Supply 5" WC (1.25 kpa) Periodically check the pilot flames. Correct 1) 6 Stage flame adjustment Pressure flame pattern has two strong blue flames: 2) Pilot adjustment 1 flowing around the flame sensor and 1...
  • Page 56: Wiring Diagram

    911-311 PFII IFC Board 911-189 SIT Gas Valve LP Lamp Green to Ground 946-799 SIT WIFI Dongle Kit User Interface 911-344 Power Harness w/Aux Comfort Fan Connector Split Flow 911-253- Main Line Motor 911-272 Variable Lights | City Series CV40E-12...
  • Page 57: Vent Chart For Power Vent Only Horizontal Terminations - Inline Horizontal Vent Chart

    90-degree elbow. See example above. Vent Restrictor Position (In Line) Vent Restrictor Position No vent restrictor required. Set 0 Set 0 Fully open Fully open Factory Set Factory Set 3 1 8 " City Series CV40E-12 | 920-210b 09.22.20...
  • Page 58: Horizontal Terminations - End Of Line Horizontal Vent Chart

    One 90° elbow = two 45° elbows. • • Minimum 4' (1.2 m) from the unit prior to terminating. Minimum 4' (1.2 m) from the unit prior to terminating. Vent Restrictor Position (End of Line) 1" (25mm) | City Series CV40E-12...
  • Page 59: Inner Glass Panel (Firebox Glass) Installation / Removal

    4. Lift up the front panel using the supplied vacuum clamps and position into the lower front channel–ensure the front panel is accurately centered—with the front panel in position—secure in place by closing the 3 lower clamps and 4 upper clamps. City Series CV40E-12 |...
  • Page 60: Outer Safety Glass Panel (Barrier Glass) Installation / Removal

    Clockwise = bring panel 2. Using the supplied vacuum clamps, lift the large front glass panel and Counter clockwise= bring position it front and centre by manoeuvering up and underneath the front panel out of the unit frame. | City Series CV40E-12...
  • Page 61: Lp Conversion Instructions

    9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re- situate the IFC, secure the screws that fasten the IFC Mounting Brackets. 10. Remove pilot hood by lifting up and off. Cable from motor 920-040 02.13.19 City Series CV40E-12 |...
  • Page 62 2.9" WC (0.72 kpa) Orifice Size #53 DMS Maximum Input 28,500 Btu/h (8.35 kW) Minimum Input 15,500 Btu/h (4.54 KW) Altitude 0-4500 ft (0-1372m) Pilot retainer clip Installer Notice: These instructions must be left with the appliance | City Series CV40E-12 920-040 02.13.19...
  • Page 63: Wall Mount On / Off Switch And Battery Holder Installation

    Proflame Battery Holder REMOTE Item Part No. Description Slider Switch (included with wall plate) 911-335 Wall Plate - White 911-343 Wall Plate - Black 911-337/P Battery Holder J-Box 910-369 Low Voltage Junction Box 911-181 Battery Holder Wire Harness City Series CV40E-12 |...
  • Page 64: Proflame Wall Mount Transmitter

    - Fix the adapter on the wall using the mounting hardware supplied with the remote control. - Insert the remote control onto the adapter as shown in Fig. B. Fig. A: Detach the adapter from the body Fig. B: Adapter and remote control | City Series CV40E-12...
  • Page 65: Clean Trim Faceplate Installation

    5. Affix Clean Trim Faceplate with self-tapping screws that are included in 2. Prior to installing outer liner panels and barrier glass remove finishing trim the box. plates from right and left sides. 3. Insert Clean Trim Faceplate into fireplace opening. 04.17.20 920-259 City Series CV40E-12 |...
  • Page 66: Painted Panel Installation

    Outer Panels The CV40E can be equipped with optional steel inner panels. 1. Attach Regency logo to the right hand side of outer front panel. The CV40E - 3 outer panels and 4 inner panels. magnets will be positioned under the outer front base panel to secure the logo.
  • Page 67: Glass Panel Installation

    5. Install metal panel (3) into of front firebox panel. 12. Install media and inner firebox glass prior to next step. 13. Install outer front panel (1) as shown. Secure Regency logo to underside of outer front panel. The logo is simply held in with magnets.
  • Page 68: Enamel Panel Installation

    — see manual for instructions. 3. Install back enamel panel - manoeuvre panel into unit and position 2. Attach Regency logo to the right hand side of outer front panel. The magnets panel at back wall of firebox. will be positioned under the outer front base panel to secure the logo. Install NOTE: Side panels when secured, will hold back panel in position.
  • Page 69: Extended View Panel Installation

    3. Attach left and right base panels using 2 screws on each side. Re- move drywall finishing edge from right and left side of window open- ing using supplied right-angle screwdriver. Secure base panels Attach base panels City Series CV40E-12 |...
  • Page 70 9. Finish up to the dashed line on the base part—DO NOT finish past this line. Finish to the dashed line only Correctly installed glass panels NOTE: Remove side liner panel and extended view panel to access firebox. Base panel with finishing | City Series CV40E-12 01.13.20 919-809...
  • Page 71: Burner And Firebox Media Options

    * Media not supplied with unit - must be purchased separately. Natural / Ivory Stones + Fireglass 3/4" Crushed black glass + Black Fireglass Spa Stones + Fireglass Starfire Fireglass + Iceburg chips Fireglass + Firebeads Stone River Pebbles + Fireglass Lava Embers + Black Fireglass City Series CV40E-12 |...
  • Page 72: Optional Driftwood Log Set Installation

    The logs are fragile, handle with care—never force into position. 4. Install Black Fireglass (1.5lb) and glowing wool on the burner as shown below. 3/4" away from the edge of the burner Burner covered with Fireglass and glowing wool Log 2 in position 10.03.18 919-651b | City Series CV40E-12...
  • Page 73 fl ow Add lava rock sparsely around the perimeter of the burner. 11. Place Log 4—identify the pin locator and match with the left side pin on Log 1. Pin in Log 1 Completed Install City Series CV40E-12 | 919-651b 10.03.18...
  • Page 74: Optional Birchwood Log Set Installation

    3. Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care—never force into position. 4. Install Black Fireglass (1.5lb) and glowing wool on the burner as shown below. Log 1 in position | City Series CV40E-12 920-074 02.28.19...
  • Page 75 NOTE: Ensure the installed optional media doesn't completely block the air flow—ensure more than 50% of the airflow is open (shown with 3/4" crushed black glass). Completed Install Do not completely block air flow City Series CV40E-12 | 920-074 02.28.19...
  • Page 76: Optional Splitwood Log Set Installation

    The logs are fragile, handle with care—never force into position. 4. Install Black Fireglass (1.5lb) and glowing wool on the burner as shown below. Log 1 in position Burner covered with Fireglass and glowing wool 08.26.19 920-086 | City Series CV40E-12...
  • Page 77 NOTE: Ensure the installed optional media doesn't completely block the air fl ow—ensure more than 50% of the airfl ow is open (shown with 3/4" crushed black glass). Do not completely block air fl ow Log 5 in position Completed Install City Series CV40E-12 | 920-086 08.26.19...
  • Page 78: Tv Kit Installation

    5. Run the BX cable from the back of the electrical box and route through the framing using the supplied ties (use larger holes in framing to accom- modate cable ties). BX cable secured using cable ties | City Series CV40E-12 919-689b 06.12.17...
  • Page 79 9. After applying the fi nishing material to the framing kit.—secure TV kit 10. When using wall fi nishes other than Regency's wall panels, in conjunction trim piece with 2 screws as shown below. with the compact/extended framing kit, adhere to the measurements shown below, for the TV wiring kit.
  • Page 80: Operating Instructions

    WHILE IT IS HOT. Back screw locations CB40E shown 3. Reverse steps to reinstall burner. Minimum Air Shutter Opening: 1/16" 3/8" Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. | City Series CV40E-12...
  • Page 81: Maintenance Instructions

    For relighting, refer to lighting instructions. Keep 4. Inspect joints, to verify that no pipe sections or Regency dealer only. Replacement glass is shipped the burner and control compartment clean by fittings have been disturbed, and consequently already installed into the door frame.
  • Page 82: Bulb Replacement

    NOTE: Do not handle bulb with bare hands. Use packaging or a tissue to hold new bulb when replacing. Regency Part# 911-208 Oven Lamp Assembly G9 120V/25W Regency Part# 911-072 Replacement Bulb G9 120 Volt/25 watt | City Series CV40E-12...
  • Page 83: Valve Replacement

    6. Loosen 4 screws in locations shown below (2 at front and 2 at rear)—slide burner to the left away from the orifice and lift out. Front screw locations 9. Reverse steps 6-1 to complete. Back screw locations CB40E shown City Series CV40E-12 |...
  • Page 84: Gas Maintenance - Recommended Annual Routine

    • Burner orifice • Burner media (change as needed) • Thermocouple (millivolt models) • Air shutter setting • Thermopile (millivolt models) • Wiring Gas Leak Tests • Check main gas line connection to valve • Check shut off valve connections • Check connection at gas valve outlet • Check connection at main burner orifice • Check pilot fuel line at valve and at pilot assembly 920-324 09.14.20 | City Series CV40E-12...
  • Page 85: Parts List

    Flush Inner Ceramic Glass 904-970 Magnet Cup 1/2 inch (Each) 656-062 Outer Base Cover Black 948-223 Logo Plate Plastic Regency/Flame Silver 936-219 Gasket 5/8 (09) Sewn Rope Graphite 3/4 PSA 10 656-550 Logo Mounting Bracket (Sold per Foot 10 Feet Required)
  • Page 86: Main Assembly

    946-740 Firebeads Sangria Luster 5 Lb Pkg 946-741 Firebeads Glacier Ice 5 Lb Pkg 946-742 Firebeads Caramel Luster 5 Lb Pkg 946-710 Stones -Slate/Grey Basalt Natural 15 lbs 946-711 Stones - Ivory/Tan Basalt Natural 15 lbs | City Series CV40E-12...
  • Page 87 City Series CV40E-12 |...
  • Page 88: Power Vent

    Silicone Hose (sold per foot/1 foot required) 3RD ANGLE TOLERANCES UNLESS FIREPLACE PRODUCTS MAT'L : PROJECTION OTHERWISE STATED INTERNATIONAL | City Series CV40E-12 SHEAR/ PUNCH/ FORM DIMENSIONS PROCESS : 0.000 = 0.01 CRITICAL INLINE POWER VETN ASSEMBLY SCALE: PART : 0.000 = SPECIFIED TOLERANCE...
  • Page 89 City Series CV40E-12 |...
  • Page 90: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty | City Series CV40E-12...
  • Page 91 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty City Series CV40E-12 |...
  • Page 92 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 93 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 94 | City Series CV40E-12...
  • Page 95 City Series CV40E-12 |...
  • Page 96 Dealer Name & Address: _______________________________________ ___________________________________________________________ Installer: ___________________________________________________ Phone #: ___________________________________________________ Date Installed: _______________________________________________ Serial #: ____________________________________________________ Printed in Canada Regency and City Series are trademarks of FPI Fireplace Products International Ltd. © Copyright 2022, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

City series

Table of Contents